SummaryA quality control scheme has been developed to achieve reproducible capillary GC characterization of crude oils and petroleum condensates. The method uses an internal standard to quantify the amount of non-eluted material in the crude oil sample. Correlation between the gas chromatographic results and actual distillation was 2 %. After repeated use, however, weekly analysis of the same standard crude oil did not give the correct composition. This was a result of discrimination, which worsened with time, as a result of leaks in the septum or the graphite ferrules. More reproducible results were obtained by performing frequent analyses of quality control samples to ensure that the gas chromatographic system was operating properly. The use of quality control charts was a convenient way of ensuring correct operation and identifying the need for corrective action on the gas chromatographic system.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.