: Collagen cross-linking is a promising procedure for the treatment of progressive keratoconus with minimal reported side effects. However, the possibility of a secondary infection after the procedure exists because the patient is subjected to epithelial debridement and the application of a soft contact lens. The role of the UV light on the immune mechanisms of the cornea and its effect on corneal wound healing warrant further investigation.
Acanthamoeba keratitis is a rare infection, and contact lens wear remains the commonest association, with poor hygiene constituting significant additional risk. The visual outcome has improved with the availability of effective amoebicidal agents, but patients with a diagnostic delay and non-contact lens wearers are at increased risk of recurrent disease. A high index of clinical suspicion remains the most effective strategy in implementing early treatment, and enabling a favourable outcome.
ABSTRACT.Purpose: To assess the agreement between a Scheimpflug camera (Pentacam) and a combined Placido-optical coherence tomography device (Visante OMNI) in measuring corneal curvature, thickness and elevation values in normal and keratoconic eyes. Methods: Corneal measurements of 110 normal eyes (one eye per subject) and 70 keratoconic eyes were obtained from both devices and compared. Agreement was determined using the Bland-Altman analysis 95% limits of agreement (LoA). Results: The Pentacam measured significantly greater keratometry readings in the flattest (K1) and steepest meridians (K2) in normal and keratoconic eyes. The 95% LoA in normal eyes were À0.32 to 0.59 dioptres (D) (K1) and À0.41 to 0.74 D (K2). In keratoconic eyes, the 95% LoA were À1.35 to 1.92 D (K1) and À1.38 to 1.99 D (K2). The Pentacam recorded significantly higher central corneal thickness (CCT) values in both groups of eyes. The 95% LoA were À4.31 to 39.89 microns (l) and À12.92 to 41.35 l in normal and keratoconic eyes, respectively. Pentacam anterior and posterior corneal elevations were significantly greater in both groups of eyes. The devices demonstrated excellent repeatability and reproducibility for corneal curvature and thickness but not elevation measurements. Conclusions: The Pentacam measured significantly greater corneal curvature, thickness and elevation values compared to the Visante OMNI in normal and keratoconic eyes. The devices agree moderately for anterior corneal elevations in normal eyes and do not appear to be interchangeable for corneal measurements in clinical practice.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.