SUMMARY Background Craniotomy, when evaluated in trials, does not improve outcome after intracerebral haemorrhage (ICH). Whether minimally invasive catheter evacuation followed by thrombolysis is safe and can achieve a good functional outcome by removing clot is unknown. We investigated safety and efficacy of alteplase with minimally invasive surgery (MIS) in patients with intracerebral haemorrhage. Methods MISTIE was an international, randomized, open-label study and was done in 26 hospitals in the USA, Canada, the UK, and Germany. Patients (aged 18–80 years), with non-traumatic (spontaneous) ICH ≥20 mL were randomly allocated, centrally, to medical care or image-guided MIS plus rt-PA (0.3 mg or 1.0 mg every 8 hours for up to 9 doses) to remove clot using surgical aspiration followed with alteplase clot irrigation. The primary efficacy outcome was the adjusted dichotomized modified Rankin Scale (mRS) 0–3 vs 4–6 assessed at day 180 after symptom onset. Analysis was by intention to treat. (ClinicalTrials.gov number NCT00224770). Findings Between February 2, 2006 and April 8, 2013, 96 subjects were randomized and completed follow-up: 54 received treatment and 42 medical care. Primary safety outcomes: mortality, symptomatic bleeding, brain infections, as well as withdrawal of care, did not differ between groups. Asymptomatic hemorrhages were more common in the surgical group (3 (7%) vs. 12 (22%) p= 0.05) producing a difference of 15.1% (95% CI: 1.5% to 28.6%). The estimated absolute benefit, i.e., the unadjusted difference in observed proportions of all subjects with mRS 0–3 (33% vs 21%) at 180 days comparing MISPA vs. medical control, is 0.109 [95%CI: −0.088, 0.294; p=0.26], and is 0.162 [95%CI: 0.003, 0.323; p=0.05] after adjustment for potential imbalances in baseline severity between study arms (primary efficacy outcome). Interpretation MIS+rt-PA appears safe with an apparent advantage of better functional outcome at 180 days. Increased asymptomatic bleeding is a major cautionary finding. The MISTIE trial results, if replicable, could produce a meaningful functional benefit adding surgical management as a therapeutic strategy for ICH. Funding National Institute of Neurologic Disorders and Stroke, Genentech, and Codman.
Summary Background Intraventricular haemorrhage is a subtype of intracerebral haemorrhage, with 50% mortality and serious disability for survivors. We aimed to test whether attempting to remove intraventricular haemorrhage with alteplase versus saline irrigation improved functional outcome. Methods In this randomised, double-blinded, placebo-controlled, multiregional trial (CLEAR III), participants with a routinely placed extraventricular drain, in the intensive care unit with stable, non-traumatic intracerebral haemorrhage volume less than 30 mL, intraventricular haemorrhage obstructing the 3rd or 4th ventricles, and no underlying pathology were adaptively randomly assigned (1:1), via a web-based system to receive up to 12 doses, 8 h apart of 1 mg of alteplase or 0·9% saline via the extraventricular drain. The treating physician, clinical research staff, and participants were masked to treatment assignment. CT scans were obtained every 24 h throughout dosing. The primary efficacy outcome was good functional outcome, defined as a modified Rankin Scale score (mRS) of 3 or less at 180 days per central adjudication by blinded evaluators. This study is registered with ClinicalTrials.gov, NCT00784134. Findings Between Sept 18, 2009, and Jan 13, 2015, 500 patients were randomised: 249 to the alteplase group and 251 to the saline group. 180-day follow-up data were available for analysis from 246 of 249 participants in the alteplase group and 245 of 251 participants in the placebo group. The primary efficacy outcome was similar in each group (good outcome in alteplase group 48% vs saline 45%; risk ratio [RR] 1·06 [95% CI 0·88–1·28; p=0–554]). A difference of 3·5% (RR 1·08 [95% CI 0·90–1·29], p=0–420) was found after adjustment for intraventricular haemorrhage size and thalamic intracerebral haemorrhage. At 180 days, the treatment group had lower case fatality (46 [18%] vs saline 73 [29%], hazard ratio 0·60 [95% CI 0·41–0·86], p=0–006), but a greater proportion with mRS 5 (42 [17%] vs 21 [9%]; RR 1·99 [95% CI 1·22–3·26], p=0–007). Ventriculitis (17 [7%] alteplase vs 31 [12%] saline; RR 0·55 [95% CI 0·31–0·97], p=0–048) and serious adverse events (114 [46%] alteplase vs 151 [60%] saline; RR 0·76 [95% CI 0·64–0·90], p=0–002) were less frequent with alteplase treatment. Symptomatic bleeding (six [2%] in the alteplase group vs five [2%] in the saline group; RR 1·21 [95% CI 0·37–3·91], p=0–771) was similar. Interpretation In patients with intraventricular haemorrhage and a routine extraventricular drain, irrigation with alteplase did not substantially improve functional outcomes at the mRS 3 cutoff compared with irrigation with saline. Protocol-based use of alteplase with extraventricular drain seems safe. Future investigation is needed to determine whether a greater frequency of complete intraventricular haemorrhage removal via alteplase produces gains in functional status.
Recent studies have illustrated that motion-related artifacts remain in resting-state fMRI (rs-fMRI) data even after common corrective processing procedures have been applied, but the extent to which head motion distorts the data may be modulated by the corrective approach taken. We compare two different methods for estimating nuisance signals from tissues not expected to exhibit BOLD fMRI signals of neuronal origin: 1) the more commonly used mean signal method and 2) the principal components analysis approach (aCompCor: Behzadi et al., 2007). Further, we investigate the added benefit of “scrubbing” (Power et al., 2012) following both methods. We demonstrate that the use of aCompCor removes motion artifacts more effectively than tissue-mean signal regression. In addition, inclusion of more components from anatomically defined regions of no interest better mitigates motion-related artifacts and improves the specificity of functional connectivity estimates. While scrubbing further attenuates motion-related artifacts when mean signals are used, scrubbing provides no additional benefit in terms of motion artifact reduction or connectivity specificity when using aCompCor.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.