Patient demand and surgeon interest in hip resurfacing has recently increased, but surgeons in the United States are relatively inexperienced with this procedure. We determined the learning curve associated with hip resurfacing and compared the rate of early complications of the first 650 hip resurfacings between five experienced hip surgeons and a national safety survey database study we previously published, which included 89 surgeons and 537 hip resurfacings. Patient demographics and adverse events were recorded. Specific features on pre-and postoperative radiographs were measured in a blinded fashion by a single observer. There were 13 major complications (2.0%), which is 3.7 times lower than our national safety survey complication rate of 7.4%. All fractures occurred in the first 25 cases performed. The complication rate was higher for the first 25 procedures (5.6%) compared with the second 25 procedures (1
Previous data on the survivorship of the Birmingham Hip Resurfacing (BHR) implant have come from design surgeons and large national databases outside of the United States, and there is a lack of reported outcomes of surface replacement arthroplasty from US centers. A retrospective study was undertaken of 1271 hips treated with a BHR system (Smith & Nephew, Memphis, Tennessee) between June 2006 and September 2008 at 6 high-volume total joint centers in the United States. Demographic features, Harris Hip Score (HHS), and radiographic findings were recorded. Patients who did not have a 2-year follow-up visit were contacted by telephone. All patients were asked about complications, reoperations, or failure of the implants. Of the treated hips, 1144 (90%) had a minimum of 2 years of clinical follow-up (mean, 2.9 years; range, 1.8-4.2 years). Mean age was 52.3 years, and 75% of patients were men. Mean HHS improved from 55.8 preoperatively to 97.4 at the most recent follow-up (P<.001). There were 16 (1.4%) revisions to total hip arthroplasty (THA) for fracture (7), early dislocation (3), acetabular component malpositioning with pain (3; 1 with metallosis), infection (1), femoral loosening (1), and pseudotumor (1). There were 9 additional complications (0.8%) that did not require revision, including 3 dislocations treated with closed reduction, 2 fractures, 3 nerve injuries, and 1 pseudotumor. At 2 to 4 years of follow-up, the revision rate and the major complication rate with the BHR system were similar to those in previous reports of primary THA. Excellent clinical results were observed, but further follow-up is necessary to assess mid- and long-term results with the BHR system in US patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.