This paper presents a continuation of projects spanning the last two years. In year one, the physical characteristics and medical effects of burns and Improvised Explosive Device, IED, blasts were investigated [1]. In year two, the possible use of commercial intumescent materials with fabric was studied [2]. The identified needs for research into the effect of undergarments on burn protection are focused in this study. Additionally, Thermal Protective Performance, TPP-(ISO 17492) and Air Permeability, AP-(ASTM D737) tests were performed to gather the data needed for the analysis of flame and thermal resistance as well as comfort and breathability. Out of the seven samples evaluated, the Sample D, composed of 94% m-aramid, 5 % p-aramid and 1% static dissipative fiber, shirt had the best overall performance in terms of air permeability, average TPP rating, and time to second degree burn. Another finding was that polyester undershirts may be dangerous in the event of a flash fire situation because the fabric could melt and stick to the Soldier's skin causing more severe burn injury. Additionally, an initial framework for a basic mathematical model representing the system was created. This model can be further refined to yield more accurate results and eventually be used to help predict the material properties required in fabrics to design a more protective undergarment.Public reporting burden for the collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Washington Headquarters Services, Directorate for Information Operations and Reports, 1215 Jefferson Davis Highway, Suite 1204, Arlington VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to a penalty for failing to comply with a collection of information if it
Soldiers, first responders and other high risk occupations such as power line technicians are routinely exposed to dangerous situations where severe burn injuries are possible. Standard flame resistant (FR) fabrics provide minimal burn protection when exposed to a flash flame incident. As a result, improvement in thermal protection is desperately needed and remains an ongoing subject of research and development. A simplified one dimensional physical model composed of a muscle layer, skin/fat layer, air gap(s) and fabric layer(s) is used to model heat transfer entering the body covered by a garment that is exposed to a flash flame. Heat transfer within the skin and muscle layers is modeled by combined conduction, metabolic heat generation and blood perfusion by a recently developed modification to the heat equation termed the bio-heat equation. Boundary conditions include a fixed temperature (core body temperature) at the inside of the muscle layer and combined convection and radiation from the flame on the outside of the fabric. The heat equation is solved by discretizing the domain in one dimension and using a finite volume approach to derive the finite difference equations. This model is an initial step to be used to provide an assessment of common FR garments with respect to both comfort in ambient conditions and protection during a flash flame. It also provides for parametric analysis to determine ideal thermo-physical properties, fabric thicknesses and layering for better protection during flash flame incidents. Estimates for time to burn injury from the numerical model is presented with experimental results using live mannequin flame tests (ASTMF-1930), standard vertical flame tests (ISO-17492) and a non-standard flame test with combined convection and radiation heat fluxes up to 85 kW/m2. The main effort of this study revolves around an initial working design for a dynamic garment termed On Demand Thermal Protection (ODTP). The primary focus of the design is the development of a thermistor circuit embedded in a protective garment to act as an electric sensor for rapidly deploying the necessary thermal protection that is needed as predicted by the numerical model instantaneously in the event of a flash flame incident. An initial prototype is being developed with a focus on designing the thermistor circuit to mechanically actuate protective components in a flash-flame environment. Concepts include rapidly releasing a pressurized flame retardant fluid through vinyl tubing sewn into a garment and deploying a protective barrier around the face and neck when the thermistor circuit detects a sudden change in heat transfer. A summary of the prototype along with experimental testing to date compared to the theoretical predictions from the model described above is presented.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.