Brain-computer interface (BCI) technology aims to help individuals with disability to control assistive devices and reanimate paralyzed limbs. Our study investigated the feasibility of an electrocorticography (ECoG)-based BCI system in an individual with tetraplegia caused by C4 level spinal cord injury. ECoG signals were recorded with a high-density 32-electrode grid over the hand and arm area of the left sensorimotor cortex. The participant was able to voluntarily activate his sensorimotor cortex using attempted movements, with distinct cortical activity patterns for different segments of the upper limb. Using only brain activity, the participant achieved robust control of 3D cursor movement. The ECoG grid was explanted 28 days post-implantation with no adverse effect. This study demonstrates that ECoG signals recorded from the sensorimotor cortex can be used for real-time device control in paralyzed individuals.
This paper summarizes two novel ways to extend brain-computer interface (BCI) systems. One way involves hybrid BCIs. A hybrid BCI is a system that combines a BCI with another device to help people send information. Different types of hybrid BCIs are discussed, along with challenges and issues. BCIs are also being extended through intelligent systems. Software that allows high-level control, incorporates context and the environment and/or uses virtual reality can substantially improve BCI systems. Throughout the paper, we critically address the real benefits of these improvements relative to existing technology and practices. We also present new challenges that are likely to emerge as these novel BCI directions become more widespread.
This paper demonstrates a synergy-based brain-machine interface that uses low-dimensional command signals to control a high dimensional virtual hand. First, temporal postural synergies were extracted from the angular velocities of finger joints of five healthy subjects when they performed hand movements that were similar to activities of daily living. Two synergies inspired from the extracted synergies, namely, two-finger pinch and whole-hand grasp, were used in real-time brain control, where a virtual hand with 10 degrees of freedom was controlled to grasp or pinch virtual objects. These two synergies were controlled by electrocorticographic (ECoG) signals recorded from two electrodes of an electrode array that spanned motor and speech areas of an individual with intractable epilepsy, thus demonstrating closed loop control of a synergy-based brain-machine interface.
In the presented work, standard and high-density electrocorticographic (ECoG) electrodes were used to record cortical field potentials in three human subjects during a hand posture task requiring the application of specific levels of force during grasping. We show two-class classification accuracies of up to 80% are obtained when classifying between two-finger pinch and whole-hand grasp hand postures despite differences in applied force levels across trials. Furthermore, we show that a four-class classification accuracy of 50% is achieved when predicting both hand posture and force level during a two-force, two-hand-posture grasping task, with hand posture most reliably predicted during high-force trials. These results suggest that the application of force plays a significant role in ECoG signal modulation observed during motor tasks, emphasizing the potential for electrocorticography to serve as a source of control signals for dexterous neuroprosthetic devices.
This paper presents “Craniux,” an open-access, open-source software framework for brain-machine interface (BMI) research. Developed in LabVIEW, a high-level graphical programming environment, Craniux offers both out-of-the-box functionality and a modular BMI software framework that is easily extendable. Specifically, it allows researchers to take advantage of multiple features inherent to the LabVIEW environment for on-the-fly data visualization, parallel processing, multithreading, and data saving. This paper introduces the basic features and system architecture of Craniux and describes the validation of the system under real-time BMI operation using simulated and real electrocorticographic (ECoG) signals. Our results indicate that Craniux is able to operate consistently in real time, enabling a seamless work flow to achieve brain control of cursor movement. The Craniux software framework is made available to the scientific research community to provide a LabVIEW-based BMI software platform for future BMI research and development.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.