Purpose To substantially shorten the acquisition time required for quantitative three‐dimensional (3D) chemical exchange saturation transfer (CEST) and semisolid magnetization transfer (MT) imaging and allow for rapid chemical exchange parameter map reconstruction. Methods Three‐dimensional CEST and MT magnetic resonance fingerprinting (MRF) datasets of L‐arginine phantoms, whole‐brains, and calf muscles from healthy volunteers, cancer patients, and cardiac patients were acquired using 3T clinical scanners at three different sites, using three different scanner models and coils. A saturation transfer‐oriented generative adversarial network (GAN‐ST) supervised framework was then designed and trained to learn the mapping from a reduced input data space to the quantitative exchange parameter space, while preserving perceptual and quantitative content. Results The GAN‐ST 3D acquisition time was 42–52 s, 70% shorter than CEST‐MRF. The quantitative reconstruction of the entire brain took 0.8 s. An excellent agreement was observed between the ground truth and GAN‐based L‐arginine concentration and pH values (Pearson's r > 0.95, ICC > 0.88, NRMSE < 3%). GAN‐ST images from a brain‐tumor subject yielded a semi‐solid volume fraction and exchange rate NRMSE of 3.8prefix±1.3%$$ 3.8\pm 1.3\% $$ and 4.6prefix±1.3%$$ 4.6\pm 1.3\% $$, respectively, and SSIM of 96.3prefix±1.6%$$ 96.3\pm 1.6\% $$ and 95.0prefix±2.4%$$ 95.0\pm 2.4\% $$, respectively. The mapping of the calf‐muscle exchange parameters in a cardiac patient, yielded NRMSE < 7% and SSIM > 94% for the semi‐solid exchange parameters. In regions with large susceptibility artifacts, GAN‐ST has demonstrated improved performance and reduced noise compared to MRF. Conclusion GAN‐ST can substantially reduce the acquisition time for quantitative semi‐solid MT/CEST mapping, while retaining performance even when facing pathologies and scanner models that were not available during training.
Wirelessly powered microdevices are being miniaturized to improve safety, longevity, and spatial resolution in a wide range of biomedical applications. Some wireless microdevices have reached a point where they can be injected whole into the central nervous system. However, the state-of-the-art floating microdevices have not yet been tested in chronic brain applications, and there is a growing concern that the implants might migrate through neural tissue over time. Using a 9.4T MRI scanner, we attempt to address the migration question by tracking ultra-small devices injected in different areas of the brain (cortico-subcortical) of rats over 5 months. We demonstrate that injectable microdevices smaller than 0.01 mm3 remain anchored in the brain at the targeted injection site over this time period. Based on CD68 (microglia) and GFAP (astrocytes) immunoreactivity to the microdevice, we hypothesize that glial scar formation is preventing the migration of chronically implanted microdevices in the brain over time.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.