Early recurrent hemodynamically significant stenosis is unusual and rarely progresses to occlusion. Even critical stenosis can regress to within normal limits. Redo endarterectomy is seldom necessary. The challenge remains to define which patients are at risk for symptoms and occlusion.
Background: Conflicting results from previous studies have led to dissent over whether surgical mesh is safe and effective in ventral hernia repair. A newer class of mesh known as a reinforced tissue matrix, combining a biologic scaffold and minimal polymer reinforcement, offers promise in reducing inflammatory response and increasing abdominal wall support. This study sought to assess the clinical utility of a reinforced tissue matrix (OviTex) in ventral hernia repair 12 months after implantation. Methods: This is a prospective, single-arm, multi-center study to evaluate the clinical performance of OviTex® 1S Permanent (OviTex) in the repair of primary or recurrent ventral hernias (VH) in consecutive patients (ClinicalTrials.gov/NCT03074474). The rate of surgical site occurrences (SSOs) was evaluated 90 days post-surgery as the primary endpoint. Hernia recurrence and the incidence of postoperative events were evaluated between three and 12 months as secondary endpoints. The incidence of other complications and patient-reported outcomes were also recorded. Results: Ninety-two (92) patients were enrolled in the study, of whom seventy-six (76) reached the 12-month follow-up. All patients were at least 18 years of age with a BMI of <40 kg/m2. Hernia defects were <20 × 20 cm, classified as class I–III according to the CDC wound classification system. Of the 76 patients who reached 12-month follow-up, twenty-six (34%) had previous VH repairs and thirteen (17%) had previous surgical infection. Sixty (79%) had factors known to increase the risk of recurrence. Twenty patients (26%) experienced SSOs, with ten (13%) requiring procedural intervention. Two of the 75 patients (2.7%) experienced a recurrence. Conclusions: The low rate of hernia recurrence and SSOs requiring intervention illustrates the potential that reinforced tissue matrices, and OviTex 1S, in particular, have to improve outcomes in VH repairs. Follow-up to 24 months is ongoing.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.