IntroductionThe publication of explant rates has established risk factors and a definitive objective outcome of failure for spinal cord stimulation (SCS) treating neuropathic pain. We present a UK study analyzing explants of electrical neuromodulation devices for different conditions over 11 years in a single center specializing in neuromodulation.MethodsA retrospective analysis was performed using a departmental database between 2008 and 2019. Explants were analyzed according to condition, mode of stimulation and other demographics using logistic regression and Kaplan-Meier graphs with log-rank (Mantel-Cox) test.ResultsOut of a total of 1177 patients, the explant rate was 17.8% at 5 years and 25.2% at 10 years. Loss of efficacy was the most frequent reason for explant 119/181 (65%). Multivariant regression analysis indicated patients with back pain without prior surgery had a reduced risk of explant (p=0.03). Patients with SCS systems that had 10 kHz, options of multiple waveforms, and rechargeable batteries also had a decreased risk of explant (p<0.001). None of these findings were confirmed when comparing Kaplan-Meier graphs, however. Contrary to other studies, we found gender and age were not independent variables for explant.ConclusionThese data contribute to a growing list of explant data in the scientific literature and give indications of what factors contribute to long-term utilization of electrical neuromodulation devices.
BackgroundThe cricothyroid membrane (CTM) is the recommended site of access to the airway during cricothyrotomy to provide emergency oxygenation. We sought to compare the ability of physicians to correctly identify the CTM in male and female patients.MethodsIn a prospective observational study, anaesthetists were asked to locate the CTM by palpation which was then identified using ultrasound and the distance between the actual and estimated margin of the CTM was measured. Participants assessed the ease of CTM palpation using a visual analog scale. In a second series, the angulation of the posterior junction of the thyroid laminae was measured using ultrasound.Results23 anaesthetists and 44 subjects participated. A total of 36 assessments were carried out in each gender. Incorrect identification of the CTM was more common in females (29/36 vs. 11/36, P < 0.001) and the distance from the CTM in the vertical plane was greater (11.0 [6.5–20.0] vs. 0.0 [0.0–10.0] mm, P < 0.001). In females distance from the CTM correlated positively with neck circumference (P = 0.005) and BMI (P = 0.00005) and negatively with subject height (P = 0.01). Posterior thyroid cartilage angulation was greater in females (118.6 ± 9.4° vs. 95.9 ± 12.9°, P = 0.02) and was lower in patients with correctly identified CTMs (100.0 ± 14.9° vs. 115.6 ± 15.9°, P = 0.02). VRS palpation correlated with decreased posterior thyroid cartilage angulation (P = 0.04).ConclusionsCTM localisation is more difficult in female subjects irrespective of body habitus. It may be prudent to localize this structure by additional means (e.g. ultrasound) in advance of any airway manoeuvres or to modify the cricothyrotomy technique in the event that it is necessary in an emergency.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.