Mutations in TDP-43 are associated with proteinaceous inclusions in neurons and are believed to be causative in neurodegenerative diseases such as frontotemporal dementia or amyotrophic lateral sclerosis. Here we describe a Drosophila system where we have engineered the genome to replace the endogenous TDP-43 orthologue with wild type or mutant human TDP-43(hTDP-43). In contrast to other models, these flies express both mutant and wild type hTDP-43 at similar levels to those of the endogenous gene and importantly, no age-related TDP-43 accumulation observed among all the transgenic fly lines. Immunopre-cipitation of TDP-43 showed that flies with hTDP-43 mutations had increased levels of ubi-quitination and phosphorylation of the hTDP-43 protein. Furthermore, histologically, flies expressing hTDP-43 M337V showed global, robust neuronal staining for phospho-TDP. All three lines: wild type hTDP-43,-G294A and-M337V were homozygous viable, with no defects in development, life span or behaviors observed. The primary behavioral defect was that flies expressing either hTDP-43 G294A or M337V showed a faster decline with age in negative geotaxis. Together, these observations implied that neurons could handle these TDP-43 mutations by phosphorylation-and ubiquitin-dependent proteasome systems, even in a background without the wild type TDP-43. Our findings suggest that these two specific TDP-43 mutations are not inherently toxic, but may require additional environmental or genetic factors to affect longevity or survival.
Radiofrequency ablation of primary and metastatic liver tumors is becoming a potential alternative to surgical resection. We propose a novel system that uses real-time electromagnetic position sensing of the needle tip to help with precision guidance into a liver tumor. The purpose of this study was to evaluate this technology in phantom and animal models. Using an electromagnetic navigation device, instrumented 18 g needles were advanced into radioopaque tumor targets in a respiratory liver phantom. The phantom featured a moving liver target that simulated cranio-caudal liver motion due to respiration. Skin-to-target path planning and real-time needle guidance were provided by a custom-designed software interface based on pre-operative 1 mm CT data slices. Needle probes were advanced using only the electromagnetic navigation device and software display. No conventional real-time imaging was used to assist in advancing the needle to the target. Two experienced operators (interventional radiologists) and two inexperienced ones (residents) used the system. The same protocol was then also used in two anesthetized 45 kg Yorkshire swine where radioopaque agar nodules were injected into the liver to serve as targets. A total of 76 tumor targeting attempts were performed in the liver phantom, and 32 attempts were done in the swine. The average time for path planning was 30 s in the phantom, and 63 s in the swine. The median time for the actual needle puncture to reach the desired target was 33 s in the phantom, and 42 s in the swine. The average registration error between the CT coordinate system and electromagnetic coordinate system was 1.4 mm (SD 0.3 mm) in the phantom, and 1.9 mm (SD 0.4 mm) in the swine. The median distance from the final needle tip position to the center of the tumor was 6.4 mm (SD 3.3 mm, n=76) in the phantom, and 8.3 mm (SD 3.7 mm, n=32) in the swine. There was no statistical difference in the planning time, procedure time, or accuracy of needle placement between experienced and inexperienced operators. The novel electromagnetic navigation system allows probe delivery into hepatic tumors of a physiologic phantom and live anesthetized swine. The system allows less experienced operators to perform equally well as experienced radiologists in terms of procedure time and accuracy of needle probe delivery.
Pulmonary rehabilitation is an effective treatment for people with chronic obstructive pulmonary disease. However, access to these services is limited especially in rural and remote areas. Telerehabilitation has the potential to deliver pulmonary rehabilitation programs to these communities. The aim of this study was threefold: to establish the technical feasibility of transmitting real-time pulse oximetry data, determine the validity of remote measurements compared to conventional face-to-face measures, and evaluate the participants' perception of the usability of the technology. Thirty-seven healthy individuals participated in a single remote pulmonary rehabilitation exercise session, conducted using the eHAB telerehabilitation system. Validity was assessed by comparing the participant's oxygen saturation and heart rate with the data set received at the therapist's remote location. There was an 80% exact agreement between participant and therapist data sets. The mean absolute difference and Bland and Altman's limits of agreement fell within the minimum clinically important difference for both oxygen saturation and heart rate values. Participants found the system easy to use and felt confident that they would be able to use it at home. Remote measurement of pulse oximetry data for a pulmonary rehabilitation exercise session was feasible and valid when compared to conventional face-to-face methods.
Respiratory motion is a significant and challenging problem for radiation medicine. Without adequate compensation for respiratory motion, it is impossible to deliver highly conformal doses to tumors in the thorax and abdomen. The CyberKnife frameless stereotactic radiosurgery system with Synchrony provides respiratory motion adaptation by monitoring skin motion and dynamically steering the beam to follow the moving tumor. This study quantitatively evaluated this beam steering technology using optical tracking of both the linear accelerator and a ball-cube target. Respiratory motion of the target was simulated using a robotic motion platform and movement patterns recorded from previous CyberKnife patients. Our results show that Synchrony respiratory tracking can achieve sub-millimeter precision when following a moving object.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.