Craniovertebral junction (CVJ) deformity is a challenging pathology that can result in progressive deformity, myelopathy, severe neck pain, and functional disability, such as difficulty swallowing. Surgical management of CVJ deformity is complex for anatomical reasons; given the discreet relationships involved in the surrounding neurovascular structures and intricate biochemical issues, access to this region is relatively difficult. Evaluation of the reducibility, CVJ alignment, and direction of the mechanical compression may determine surgical strategy. If CVJ deformity is reducible, posterior in situ fixation may be a viable solution. If the deformity is rigid and the C1-2 facet is fixed, osteotomy may be necessary to make the C1-2 facet joint reducible. C1-2 facet release with vertical reduction technique could be useful, especially when the C1-2 facet joint is the primary pathology of CVJ kyphotic deformity or basilar invagination. The indications for transoral surgery are becoming as narrow as a treatment for CVJ deformity. In this article, we will discuss CVJ alignment and various strategies for the management of CVJ deformity and possible ways to prevent complications and improve surgical outcomes.
OBJECTIVEThe authors sought to evaluate the usefulness of indocyanine green (ICG) angiography and Doppler sonography for monitoring the vertebral artery (VA) during craniovertebral junction (CVJ) surgery and compare the incidence of VA injury (VAI) between the groups with and without the monitoring of VA using ICG angiography and Doppler sonography.METHODSIn total, 344 consecutive patients enrolled who underwent CVJ surgery. Surgery was performed without intraoperative VA monitoring tools in 262 cases (control group) and with VA monitoring tools in 82 cases (monitoring group). The authors compared the incidence of VAI between groups. The procedure times of ICG angiography, change of VA flow velocity measured by Doppler sonography, and complication were investigated.RESULTSThere were 4 VAI cases in the control group, and the incidence of VAI was 1.5%. Meanwhile, there were no VAI cases in the monitoring group. The procedure time of ICG angiography was less than 5 minutes (mean [± SD] 4.6 ± 2.1 minutes) and VA flow velocity was 11.2 ± 4.5 cm/sec. There were several cases in which the surgical method had to be changed depending on the VA monitoring. The combined use of ICG angiography and Doppler sonography was useful not only to monitor VA patency but also to assess the quality of blood flow during CVJ surgery, especially in the high-risk group of patients.CONCLUSIONSThe combined use of ICG angiography and Doppler sonography enables real-time intraoperative monitoring of the VA by detecting blood flow and flow velocity. As the arteries get closer, they provide auditory and visual feedback to the surgeon. This real-time image guidance could be a useful tool, especially for high-risk patients and inexperienced surgeons, to avoid iatrogenic VAI during any CVJ surgery.
Study Design A Retrospective Cohort Study. Objective To introduce a new Doppler sonography-assisted pedicle screw fixation technique that enables vertebral artery (VA) monitoring during surgery and compares the accuracies of Doppler sonography-assisted cervical pedicle screw fixation and the conventional technique. Methods This retrospective study was performed on 164 consecutive patients that underwent pedicle-based screw fixation from C2 to C6 between January 2013 and August 2020. Surgery was performed without intraoperative Doppler sonography in 84 cases (the Control group) or with intraoperative Doppler sonography in 80 cases (the Doppler group). Proper positioning of pedicle screws was graded, and the incidences of VA injury and screw breach in the Control and Doppler groups were compared. Results Three hundred and ninety-nine screws were placed in the 164 patients (Doppler, 186 screws; Control, 213 screws). The percentages of well-positioned screws in the two groups were significantly different (Doppler, 97.8%; Control, 85.0%). There were two cases of VA injury in the Control group, an incidence of 2.4%, but no case in the Doppler group. Conclusion Doppler sonography can be used intraoperatively to help guide the trajectory of the cervical pedicle screw insertion. It can detect the VA inside the screw trajectory and may reduce the risk of VA injury during cervical pedicle screw fixation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.