The effects of slot width for confined, laminar impinging slot jets of millimeter-scale are considered, including experimental measurements of spatially resolved distributions of local Nusselt numbers measured on a constant heat flux surface. The effects of Reynolds number, nozzle-to-plate distance, and dimensional slot width on the local Nusselt number are investigated for slot nozzle width B values of 0.5 mm, 1.0 mm, and 1.5 mm. Reynolds numbers Re range from 120 to 200, nozzle-to-plate distances H/B vary from 0.75 to 12.5, and the nozzle aspect ratio y/B is 50. Observed are different stagnation point Nusselt number Nuo variations with Re, H/B, and B, where the onset of unsteadiness, and the intermittent flapping motion of the jet column are both associated with important variations to local, stagnation region Nusselt numbers Nuo, as experimental configuration and condition change. The variations of these stagnation-point Nusselt numbers associated with these two modes of unsteadiness are characterized by correlations which provide the dependence upon Reynolds number and normalized nozzle-to-plate distance ratio, H/B, for different dimensional values of B. Also presented are stagnation region Nusselt number variations, for steady, impingement jets at values of H/B less than 4.6–7.8. These are characterized by three separate regimes of behavior, each of which shows significantly different Nuo dependence upon Re, H/B, and B.
We have developed a new innovative plate-type heat exchanger using thin aluminum foil sheet that significantly reduces the indoor pollutants with a minimum loss of energy. The thin aluminum foil sheet has a thickness of 17μm, and having a width of 330 mm and a length of 1,510 mm. The heat exchanger consists of 45 layers of aluminum foil sheets which are placed on top of each other with a spacing of 7 mm. The exchanger is structured such that air dust and pollutants can be effectively filtered as the air stream passes through the heat exchanger. The experimental results show that the concentration of carbon dioxide inside the office room is reduced to as low as 650 ppm, while maintaining the room temperature difference to within ± 1 degree Celsius before and after operating the present heat exchanger. This device can be installed in any indoor places that need the good air quality control with a little sacrifice of energy consumption.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.