Inaccurate positioning of the robot end effector causes joint deformation as well as geometric errors when an industrial robot has a payload at its end effector. We propose a new approach of calibration which deals with joint angle dependent errors to compensate for these phenomena. To implement this method, we divided the robot workspace into several local regions, and built a calibration equation by generating the constraint conditions of the end effector's motion in each local region using a three-dimensional position measurement system. The parameter errors obtained this way were interpolated using the Radial Basis Function Network (RBFN) so as to estimate calibration errors in the regions that we did not measure. We used this technique to improve the performance of a six DOF industrial robot used for arc welding.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.