The use of citrate as an anticoagulant in continuous renal replacement therapy is an effective method to achieve regional anticoagulation of the extracorporeal blood circuit and to avoid systemic anticoagulation. This allows bleeding complications to be reduced and filter life time to be prolonged. However, citrate enters the systemic circulation and is metabolized in the liver to bicarbonate, causing metabolic alkalosis in some patients. In this case report, we discuss therapeutic interventions to control the acid-base status and to restore normal pH during continuous citrate hemodialysis.
Understanding field failure and degradation modes in solar photovoltaic (PV) modules is very important for various reasons especially for this widely used technology. The University of Applied Sciences Ostwestfalen-Lippe in Höxter owns photovoltaic-modules of different cell types, sizes and operation periods in German weather conditions. This paper presents a detailed degradation investigation and performance parameters analysis for chosen samples of polycrystalline, monocrystalline and thin film modules in the laboratory and outdoor test conditions after 10 years of exposure. The obtained measurements were standardized and then compared with the warranted values of the manufacturer’s datasheets for each module type. The real outdoor measurements for the larger units show that the maximum power Pmax after 10 years of exposure for polycrystalline, monocrystalline and amorphous thin film modules had declined by: 8.47%, 37.67%, and 19.05% respectively, which translates to an annual linear degradation rates of 0.652%, 3.67%, and 1.465% for each type respectively. While the maximum power output of the smaller units had declined by 19.05%, 19.36%, and 21.75% for polycrystalline, monocrystalline and amorphous thin film modules respectively, which also translated to annual linear degradation rates of 1.48%, 1.67%, and 0.6% for each type respectively. On the other hand, the laboratory tests for these modules show that there is a clear variation with the obtained outdoor results, where the Pmax for the same larger units had declined by 39.6%, 57.4%, and 82.5% for polycrystalline, monocrystalline and thin film modules respectively, While the Pmax output of smaller units had declined by 51.2%, 39.38%, and 9.39% for polycrystalline, monocrystalline and thin film modules respectively, The comparison of the efficiency and fill factor parameters for the obtained results with the manufacturer’s data shows that the outdoor measurements introduce close results than the laboratory results. The discoloration of the encapsulant is the most frequently occurring visually observable defects on the modules.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.