The exchange membranes P81 and DE81 and Chelex-100 resin were used to perform in situ speciation of uranium in treated acid mine drainage at the Osamu Utsumi mining site, Poços de Caldas city, Southeast Brazil. To investigate possible chemical modifications in the samples during analysis, the three ligands were deployed in situ and in a laboratory (in lab). The results obtained in situ were also compared to a speciation performed using Visual MINTEQ software. Chelex-100 retained total labile U for a period of up to 48 h. The labile U fraction determined by Chelex 100 ranged from 107 ± 6% to 147 ± 44% in situ and from 115 ± 22% to 191 ± 5% in lab. DE81 retained anionic U species up to 8 h, with labile fractions ranging from 37 ± 2% to 76 ± 3% in situ and 34 ± 12% to 180 ± 17% in lab. P81 exhibited a lower efficiency in retaining U species, with concentrations ranging from 6± 2% to 19± 2% in situ and 3± 2% to 18± 2% in lab. The speciation obtained from MINTEQ suggests that the major U species were UOOH, UO(OH), UO(OH), CaUO(CO), CaUO(CO), UO(CO), and UO(CO). This result is in accordance with the results obtained in situ. Differences concerning speciation and the total and soluble U concentrations were observed between the deployments performed in situ and in the laboratory, indicating that U speciation must be performed in situ.
Amberlite IRA-410 anionic exchange resin was evaluated as the binding layer for sampling V(V) by using Diffusive Gradients in Thin Films (DGT). V(V) was determined by inductively coupled plasma mass spectrometry (ICP-MS). Mass vs. time DGT deployments (ionic strength = 0.03 mol L NaNO, pH = 5.6 and T = 23.5 ± 0.5 °C) was characterized by excellent linear relationship (R = 0.9993) and a significant retention of V(V) by the binding layer. An exchange capacity of at least 40 μg V g resin was achieved for the proposed binding layer. The diffusion coefficient obtained (7.13 ± 0.6 10 cm s) agrees with the literature. The accumulation rate of V(V) was not significantly affected by ionic strength of solutions up to 0.03 mol L and for the entire studied pH range (from 3 to 9). Furthermore, when comparing the concentrations obtained using IRA-410-DGT and those obtained by direct measurement of the solution concentrations, the proposed approach provided a reduction of the ClO interference on V(V) determination by ICP-MS. Determination of V in normal mode (without collision cell) in solutions containing analyte:Cl concentration ratio up to 1:500,000 was not affected by interference of ClO polyatomic ion even when normal mode ICP-MS was used. Potential interfering ions on sampling V(V) by DGT (PO and SO) showed no significant effects on the accumulation rate of V(V). Laboratory tests performed using synthetic samples, natural freshwater and acid drainage water showed an excellent performance (recoveries from 93% to 110%). For in situ deployment, measurements of V(V) by the proposed approach was not significantly different (95.5%) from the value of dissolved V concentration.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.