Introduction Disc degeneration in the cervical spine is a prevalent clinical predicament often requiring surgery. Anterior cervical decompression and fusion (ACDF), the most commonly performed procedure, poses risks of pseudoarthrosis, and adjacent segment disease (ASD).1,2 An emerging alternative treatment option is prosthetic total disc replacement (TDR),3 which preserves segmental mobility. Our group previously developed a biological TDR device using composite AF/NP disc-like construct with viable cells and mechanical properties analogous to the native discs in a rat tail model.4 In this study, we evaluated the in vivo efficacy of this tissue-engineered intervertebral disc (TE–IVD) in a beagle cervical model assessing radiological and histological parameters. Material and Methods TE-IVD construction: Canine-sized TE–IVDs were constructed as previously described.4 Cervical IVDs from skeletally mature beagles were separated into AF and NP tissues; component cells were isolated and cultured in vitro. Cultured NP cells were seeded with alginate, injected into a predesigned mold, and encircled with two layers of an AF cell laden collagen gel. The combined construct was kept in media for 2 weeks as the surrounding annulus fibrous aligned and contracted until required TE–IVD diameter was attained. Experimental Protocol: Overall, eight skeletally mature beagles were divided into the following two groups: the control group ( n = 2) underwent discectomy with fully resected IVDs, and the experimental group ( n = 6) underwent TE–IVD implantation postdiscectomy. Adjacent proximal segments served as internal healthy controls. Postoperative X-ray and MRI were taken at 2 and 4 weeks; disc height indices5 and NP hydration using a pre-established algorithm6 were analyzed. Beagles were humanely killed at 4 weeks for histological assessment. Results TE–IVDs were successfully implanted postdiscectomy ( Fig. 1A , B). At 2 weeks, MRIs of TE–IVDs revealed T2 high intensity with acute outer inflammation because of the surgical invasion, which faded by 4 weeks. At 4 weeks, TE–IVDs maintained position in the disc space with relatively increased T2 intensity, whereas discectomized segments manifested as black discs ( Fig. 1C , D). These findings suggest that the implanted TE–IVDs engraft in the disc space despite significant biomechanical demands of the beagle cervical environment. In fact, disc height indices of the TE–IVDs and discectomized discs were 71 and 49%, respectively, of that of healthy control discs. Likewise, MRIs revealed that NP hydration of the implanted TE–IVDs was over 70% of that of healthy discs. Histological assessments further demonstrated chondrocyte-like cell viability in the TE–IVD, abundant proteoglycan content in the extracellular matrices, and substantial integration into host tissues without signs of immune reactions. [Figure: see text] Conclusion Despite the severe local milieu of the beagle cervical spine owing to mechanical loading, our in vivo TE–IVDs when appropriately implanted, maintained their position and structure at 4 weeks. The TE–IVDs displayed dynamic adaptation to the host environment, with extracellular matrix production and cell proliferation. They further maintained disc height as well as NP hydration at 4 weeks with up to 70% viability as the normal healthy discs. References Nesterenko SO, Riley LH III, Skolasky RL. Anterior cervical discectomy and fusion versus cervical disc arthroplasty: current state and trends in treatment for cervical disc pathology. Spine 2012;37(17):1470–1474 Sugawara T, Itoh Y, Hirano Y, Higashiyama N, Mizoi K. Long term outcome and adjacent disc degeneration after anterior cervical discectomy and fusion with titanium cylindrical cages. Acta Neurochir (Wien) 2009;151(4):303–309, discussion 309 Kelly MP, Mok JM, Frisch RF, Tay BK. Adjacent segment motion after anterior cervical discectomy and fusion versus Prodisc-c cervical total disk arthroplasty: analysis from a randomized, controlled trial. Spine 2011;36(15):1171–1179 Bowles RD, Gebhard HH, Härtl R, Bonassar LJ. Tissue-engineered intervertebral discs produce new matrix, maintain disc height, and restore biomechanical function to the rodent spine. Proc Natl Acad Sci U S A 2011;108(32):13106–13111 Kim JS, Kroin JS, Li X, et al. The rat intervertebral disk degeneration pain model: relationships between biological and structural alterations and pain. Arthritis Res Ther 2011;13(5):R165 Grunert P, Hudson KD, Macielak MR, et al. Assessment of intervertebral disc degeneration based on quantitative magnetic resonance imaging analysis: an in vivo study. Spine 2014;39(6):E369–E378
Introduction Despite being effective, the most commonly performed treatments for degenerative disc disease (DDD), fusion and prosthetic total disc replacement, still pose risks of pseudoarthrosis, implant dislodgement, and adjacent segment disease.1–3 Tissue engineered intervertebral discs (TE-IVD) are an alternative treatment option for DDD, and have been previously developed by our group as a biological TDR device.4 Presently, we evaluate the surgical conditions that promote implant stability and in-vivo efficacy of our TE-IVDs in a translational beagle cervical spine model. Material and Methods TE-IVD Construction: TE-IVD components were constructed in vitro using either annulus fibrosus (AF) or nucleus pulposus (NP) cultivated canine disc cells; the collagen gel based composite AF enclosed an alginate gel based composite NP, as previously described.4 Experimental and Surgical Protocol: 14 skeletally mature beagles underwent discectomy with whole IVD resection at a level between C3/4 and C6/7, and were divided into two groups: a solely discectomized control (n = 2) and a TE-IVD implanted group (n = 12). Discectomy and TE-IVD implantation were performed under segmental distraction. Implant stability was evaluated upon distraction release at the end of the procedure. Imaging: Postoperative imaging was performed with conventional X-rays and high-resolution 3-Tesla MRI under full anesthesia. Disc height indices were measured on X-rays using a pre-established method. 5 All MRIs were analyzed both qualitatively and quantitatively in accordance to T2-weighted images. Utilizing a novel algorithm developed by our group, we filtered out all MRI voxels unrepresentative of NP tissue using their T2-relaxation time (T2-RT), sequestering the extent of NP hydration based on the mean T2-RT within the NP voxel.6 Histological assessment: Animals were sacrificed either at 4 or 16 weeks. Histological staining was obtained using Safranin-O for proteoglycans. Statistics: A Chi-Squared test was performed to determine the correlation between implant stability and surgical level or posterior longitudinal ligament (PLL) resection. For the analyses of continuous outcomes in disc height index, NP size, and NP hydration, we employed linear regression models with a generalized estimating equation and robust standard errors to estimate differences in mean changes from baseline controls (discectomy) across displaced and stable implantation groups. Results TE-IVDs that demonstrated displacement of over 25% TE-IVD volume upon distraction release were defined as “displaced” implants and the remaining were termed as “stable” implants. There was a correlation between implant stability and surgical level but not between implant stability and PLL resection, with implants at C3/4 having the greatest stability (p < 0.05). Quantitative X-ray and MRI assessments showed that only the stable implants had significant retention of disc height and NP size as well as NP physiological hydration compared with discectomy controls. Both 4- and 16-week histol...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.