The design of steel and steel and concrete composite columns in a fire situation is directly linked to the reduction of strength and stiffness, among other properties, which are manifested in response to rising temperatures. The normative codes that deal with the design of these elements under the action of fire consider the thermal action based on heating on the four faces of the column, an aspect that does not cover most cases in buildings due to the presence of walls. In this context, given the importance of the correct determination of the thermal field for design purposes, as well as given the simplification adopted by the normative codes, the present work deals exclusively with a study basically aimed at obtaining a representative thermal field for purposes of thermo-structural verification of steel and steel and concrete composite columns. With the focus on the analysis of cases that differ from the prescribed configurations in standards, purely thermal numerical models are proposed, validated through experimental results, whose analyses show an evident reduction in temperature in the steel column when encased with concrete, and with even greater evidence when additionally inserted into walls as a compartmentalizing element. To verify the simplified method proposed by ABNT NBR 14323: 2013, comparative analyses between the numerical thermal fields and obtained by the standardized model were carried out for steel and steel and concrete composite cross sections. For the isolated steel columns, as expected, the normative method proved to be consistent, but conservative when it came to columns inserted into walls. In relation to the composite columns, the results obtained indicate the need for adjustment in the standards for purposes of determining the thermal field and, consequently, of design these elements.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.