Buildings play an active role in the global energy consumption and are required to not only minimize their energy use, but also generate energy in a sustainable manner. The integration of renewable energies in building elements can improve their overall performance, as they are able to replace common construction materials, while offering both electrical and thermal energy. The scope of this paper is to present the first results of an experimental study of a Building-Integrated Photovoltaic system combined with a water storage tank (BIPV-WS), a combined integration not extensively studied yet. Both layers are separated by a ventilated air cavity, and the thermal behavior of the system was analyzed experimentally in real functioning conditions. The water tank performs as a thermal storage, maintaining a regular temperature of about 20–30 °C during a typical winter day of Lisbon for a period of 11 h. Moreover, through the ventilation of the air cavity, the heat provided by the solar panel was naturally recovered to the indoors of the building, while keeping the temperature high enough to heat up the water. During summer, the ventilated BIPV-WS enabled beneficial nocturnal heat loss while delaying diurnal space heating.
The 2018 revision of the European Performance Building Directive (EPBD) requires that from the year 2020 onwards, all new buildings will have to be “nearly zero energy buildings”. It also further promotes smart building technologies, raising awareness amongst building owners and occupants of the value behind building automation. The European Commission also identified, in 2011, Key Enabling Technologies (KETs), which provide the basis for innovation in the EU. In the frame of the SUDOKET project, the Solar XXI building was used as a pilot case, as innovative integrated solutions and technologies are monitored and controlled. The objective of this paper is to validate a simulation of the laboratorial test room in EnergyPlus with data obtained experimentally and determine the impact of the control systems on energy needs and on thermal comfort. Two systems, in particular, were studied: the Building-Integrated Photovoltaic (BIPV) and the earth tubes. Once validated, the simulation of the test room without the systems was created, allowing their impact to be determined. The results show that, for the analysed periods, BIPVs reduced the heating consumption by 22% while also increasing thermal comfort, and the earth tube system would reduce the cooling needs by 97%.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.