Bamboo is a material with good tensile and flexural resistance. As a construction material with structural capacity, using bamboo implies considerable environmental advantages in relation to other typical materials such as steel or concrete. For its correct implementation, it is necessary to define its mechanical properties and durability. Bamboo is susceptible to degradation due to the lack of natural toxins and thin walls, which means that shallow decomposition processes can imply appreciable reductions in its mechanical capacity. The main degrading agents considered in this study were beetles, termites, and xylophagous fungi. The aim of this study was to analyze the durability of three different species: DS, PA, and AA. Durability and mechanical tests results after 6 months of exposure to biotic and abiotic agents were compared with their original properties and chemical composition. In this study, durability was analyzed in two ways. Firstly, the loss of mass due to fungal infection was investigated. The results obtained were based on the standard EN 113 using the fungus CP. Secondly, bending and compressive strength was evaluated after a durability test according to the standard EN 335:2013 for the CU3.1 use class after a 6 month period in the city of Donostia/San Sebastian, Spain. The DS and AA varieties were rated as very durable CD1, while the PA variety is durable CD2, thus proving to be an attractive material for construction.
This work deals with daylighting for quality indoor atmospheres, considering building skins. In recent years, almost all retrofit facades of restaurants are highly glazed façades, boosting glare, sun ray absorption and overheating inside. Most of the time, they are not integrated with daylight control; therefore, lighting and out view requirements are not so balanced. Taking into account this daylighting complexity, an alternative façade system is proposed to simulate by Radiance. Previously, perception simulations are compared with measured data, in order to discretize the simulations. In addition, for one point three different view are assessed as: work plane, relation plane and the out plane. Subsequently, two virtual façade models, windows combined by complex fenestration system (CFS) as prismatic film (PF) and highly glazed façade, are tested according to daylighting. For that, three indexes have been used: daylight glare probability (DGP), daylight glare index (DGI) and daylight autonomy (DA). The results show that the proposed complex façade has a good light contribution with less absorption, while maintaining the outside view. In addition, the DGI is needed to test the out plane, because DGP is more suitable for lower luminance; therefore, each visual plane should be assessed regarding different visual comfort conditions, or parameters and methods. Accordingly, the mean DGI result of window combined by CFS is approximately lower in 5% than highly glazed façade. However, the DA of highly glazed is higher in 5%, but the DA of window combined by CFS is enough, above 80%. Definitely, the complex scene at restaurant with the proposed integrated façade system improves light performance and indoor atmosphere.
The COVID-19 pandemic has generated a renewed interest in indoor air quality to limit viral spread. In the case of educational spaces, due to the high concentration of people and the fact that most of the existing buildings do not have any mechanical ventilation system, the different administrations have established natural ventilation protocols to guarantee an air quality that reduces risk of contagion by the SARS-CoV-2 virus after the return to the classrooms. Many of the initial protocols established a ventilation pattern that opted for continuous or intermittent ventilation to varying degrees of intensity. This study, carried out on a university campus in Spain, analyses the performance of natural ventilation activated through the information provided by monitoring and visualisation of real-time data. In order to carry out this analysis, a experiment was set up where a preliminary study of ventilation without providing information to the users was carried out, which was then compared with the result of providing live feedback to the occupants of two classrooms and an administration office in different periods of 2020, 2021 and 2022. In the administration office, a CO2-concentration-based method was applied retrospectively to assess the risk of airborne infection. This experience has served as a basis to establish a route for user-informed improvement of air quality in educational spaces in general through low-cost systems that allow a rational use of natural ventilation while helping maintain an adequate compromise between IAQ, comfort and energy consumption, without having to resort to mechanical ventilation systems.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.