Laser hair removal is currently a popular cosmetic procedure. Traditional high-fluence laser treatment for hair elimination is associated with discomfort and adverse events and it is restricted to low phototype skins. A multicenter study of hair epilation with low fluences and high repetition pulse rate using an 810-nm diode laser was carried out on 368 patients (phototypes III to V) to test its efficacy in a 6-month follow-up after five treatments on the face and various body areas. Objective and subjective assessment as well as histologies show a high index of patient satisfaction due to high efficacy of hair elimination, also proved histologically by the damage observed at hair structure level. Results obtained a high degree of patient satisfaction and a low index of adverse events. Laser epilation was well accepted regarding discomfort and was also complication-free for dark and tanned skins. Treatment is easy to conduct and requires adapting the movement of the hand-piece to a constant speed in order to achieve high-energy deposit on tissue avoiding risks of burning.
In this study, the laser at 924/975 nm combined with curettage was determined to be the optimal treatment option of those tested for axillary hyperhidrosis. This treatment was safe, with few side effects and improvement that persisted to one year follow-up.
The method leads to safe, fast and apparently permanent results. The treatment session lasts less than 1 h, and could become a first-choice treatment for the removal of all types of varicose veins with a diameter under 4 mm.
Treatment of micro-veins of less than 1.5 mm with laser and with chemical sclerosis is technically challenging because of their difficulty to remedy. Laser treatment is even more difficult when dark phototypes are involved.Three groups of 30 patients each, skin type IV, and vessels measuring less than 1.5 mm in diameter, were enrolled for two treatment sessions 8 weeks apart: group A, polidocanol (POL) micro-foam injection; group B, Nd:YAG laser alone; and group C, laser after POL injection. Repeated 8-Hz low-fluence pulses, moving the hand piece over a 3-cm vein segment with an average of five laser passes maximum and with a total time irradiation of 1 s were used. Sixteen weeks after the second treatment, statistically, degree of clearance after examining photographs and patients satisfaction index, plotted on a visual analogue scale and comparing results of all three groups, results were significantly better for group C (p<0.0001). No significant differences in complications were noticed between the three groups. Efficacy of combining POL and laser proved safe and satisfactory in 96 % of patients using low-fluence laser pulses with a total cumulative energy in the 3 cm venous segment, lower than that of conventional treatment. Very few and transient complications were observed. POL foam injection followed by laser pulses is safe and efficient for vein treatment in dark-skinned patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.