(PTB) operate cold-atom based primary frequency standards which are capable of realizing the SI second with a relative uncertainty of 1 × 10 −15 or even below. These institutes performed an intense comparison campaign of selected frequency references maintained in their laboratories during about 25 days in October/November 2004. Active hydrogen maser reference standards served as frequency references for the institutes' fountain frequency standards. Three techniques of frequency (and time) comparisons were employed. Two-way satellite time and frequency transfer (TWSTFT) was performed in an intensified measurement schedule of 12 equally spaced measurements per day. The data of dual-frequency geodetic Global Positioning System (GPS) receivers were processed to yield an ionosphere-free linear combination of the code observations from both GPS frequencies, typically referred to as GPS TAI P3 analysis. Last but not least, the same GPS raw data were separately processed, allowing GPS carrier-phase (GPS CP) based frequency comparisons to be made. These showed the lowest relative frequency instability at short averaging times of all the methods. The instability was at the level of 1 part in 10 15 at one-day averaging time using TWSTFT and GPS CP. The GPS TAI P3 analysis is capable of giving a similar quality of data after averaging over two days or longer. All techniques provided the same mean frequency difference between the standards involved within the 1σ measurement uncertainty of a few parts in 10 16. The frequency differences between the three fountains of IEN (IEN-CsF1), NPL (NPL-CsF1) and OP (OP-FO2) were evaluated. Differences lower than the 1σ measurement uncertainty were observed between NPL and OP, whereas the IEN fountain deviated by about 2σ from the other two fountains.
In this work, we demonstrate for the first time that it is possible to transfer simultaneously an ultra-stable optical frequency and precise and accurate timing over 540 km using a public telecommunication optical fiber network with Internet data. The optical phase is used to carry both the frequency information and the timestamps by modulating a very narrow optical carrier at 1.55 lm with spread spectrum signals using two-way satellite time transfer modems. The results in terms of absolute time accuracy (250 ps) and long-term timing stability (20 ps) well outperform the conventional Global Navigation Satellite System or geostationary transfer methods.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.