We conducted a retrospective, observational study of patient outcomes in two intensive care units in the same hospital. The surgical ICU (SICU) implemented telemedicine and electronic medical records, while the medical ICU (MICU) did not. Medical charts were reviewed for a one-year period before telemedicine and a one-year period afterwards. In the SICU, records were obtained for 246 patients before and 1499 patients after implementation; in the MICU, records were obtained for 220 patients and 285 patients in the same periods. The outcomes of interest were ICU length of stay and mortality, and hospital length of stay and mortality. Outcome variables were severity-adjusted using APACHE scoring. A bootstrap method, with 1000 replicates, was used to assess stability of the findings. The adjusted ICU length of stay, ICU mortality, and hospital mortality for the SICU patients all decreased significantly after the implementation of telemedicine. There was no change in adjusted outcome variables in the MICU patients. Implementation of telemedicine and electronic records in the surgical ICU was associated with a profound reduction in severity-adjusted ICU length of stay, ICU mortality, and hospital mortality. However, it is not possible to conclude definitively that the observed associations seen in the SICU were due to the intervention.
The paper presents a fingertip photoplethysmography based technique to assess patient fluid status that is robust to waveform artifacts and health variability in the underlying patient population. The technique is intended for use in intensive care units, where patients are at risk for hypovolemia, and signal artifacts and inter-patient variations in health are common. Input signals are preprocessed to remove artifact, then a parameter-invariant statistic is calculated to remove effects of patient-specific physiology. Patient data from the Physionet MIMICII database was used to evaluate the performance of this technique. The proposed method was able to detect hypovolemia within 24 hours of onset in all hypovolemic patients tested, while producing minimal false alarms over non-hypovolemic patients. Abstract-The paper presents a fingertip photoplethysmography based technique to assess patient fluid status that is robust to waveform artifacts and health variability in the underlying patient population. The technique is intended for use in intensive care units, where patients are at risk for hypovolemia, and signal artifacts and inter-patient variations in health are common. Input signals are preprocessed to remove artifact, then a parameter-invariant statistic is calculated to remove effects of patient-specific physiology. Patient data from the Physionet MIMICII database was used to evaluate the performance of this technique. The proposed method was able to detect hypovolemia within 24 hours of onset in all hypovolemic patients tested, while producing minimal false alarms over non-hypovolemic patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.