Finasteride is a potent 5 alpha-reductase inhibitor that has shown limited success in men treated for benign prostatic hyperplasia (success is defined as a decrease in the symptoms associated with urinary tract obstruction, and as increases in the urinary flow rate). 5 alpha-reductase is necessary for the prostatic conversion of testosterone to dihydrotesterone (DHT), the specific steroid that stimulates prostate transitional zone growth. Finasteride reduces the size of the prostate gland by 20%, but this does not correlate well with improvement in symptoms. Finasteride is well absorbed after oral administration and, while the rate of absorption may be slowed postprandially, the presence of food has no effect on the total bioavailability. Finasteride is widely distributed, but since its pharmacological effects are very specific to inhibition of 5 alpha-reductase, and since only the prostate gland, the scalp, and the genital skin contain high concentrations of this enzyme, few adverse reactions will be seen in other organ systems. Finasteride undergoes extensive hepatic metabolism to essentially inactive metabolites, which are eliminated through the bile and urine. The terminal elimination half-life (t1/2z) is 4.7 to 7.1 hours; but despite this, slow accumulation occurs with multiple doses. Values of t1/2z are higher in elderly men, but no dosage adjustments are necessary. Likewise, no dosage adjustments are necessary for patients with renal dysfunction, since the metabolites which accumulate are relatively inactive and well tolerated, and because greater faecal excretion of the metabolites occurs in these patients. The effect of hepatic dysfunction on the metabolism of finasteride is unknown. Therapeutic doses of finasteride produce a rapid and pronounced effect in reducing both plasma and prostate tissue levels of DHT. Doses below 0.5 mg/day do not produce much suppression of DHT levels, and doses above 5 mg/day have little additional benefit. A single dose of finasteride suppresses serum DHT levels for up to 4 days, longer than would be expected from the serum terminal elimination half-life (t1/2z) of the drug: this is probably due to the high affinity that finasteride has for the 5 alpha-reductase enzyme. Serum testosterone levels increase in patients receiving finasteride, but are not normally outside the upper limits of the normal range. Serum prostate-specific antigen (PSA) levels decrease with finasteride administration; the baseline for investigation of prostate cancer with elevated PSA levels should be one-half of the normal range. In responders to finasteride, the prostate gland shrinks in volume by about 20%, urinary flow rate improves by approximately 3 ml/s, and symptoms are relieved. The response to finasteride appears to be maximal at doses of 5 mg/day. For most men receiving finasteride, these effects will persist for at least the 5 years that long term studies have been conducted. Serum DHT levels increase again when finasteride therapy is discontinued, probably resulting in the return of the hyp...
In a prospective, single-blind, randomized study, a single 2-g dose of metronidazole was compared with a seven-day course of 500 mg given twice daily in the treatment of symptomatic vaginal discharge associated with Gardnerella vaginalis. Based on resolution of symptoms and on cultures negative for G vaginalis, 86% (40/46) of women treated with the single dose and 97% (35/36) of women treated with the seven-day course were considered cured at seven to ten days after treatment. Evaluation at 21 days after treatment, however, indicated that only 46% (16/34) of patients treated with the single 2-g dose were considered cured compared with 86% (26/30) of those treated with the seven-day course. Treatment of sexual contacts did not significantly improve cure rates in either group.
Home monitors of blood glucose (HMBGs) are gaining acceptance as part of the standard of care for ambulatory self-monitoring and treatment of diabetic patients. Currently there are several HMBGs marketed in the United States, each claiming reliability, accuracy, and "user friendliness," with most of these claims largely unsubstantiated. The objective of our study was to analyze and statistically compare the accuracy and precision of the HMBGs produced by the major competitors in this ever-expanding medical field. Accuracy of each monitor was studied by comparing the glucose value reported by each HMBG with that determined by a reference method (YSI 23A). Precision or reproducibility of results was performed by testing a single, known whole-blood glucose sample 20 times on each monitor. The precision of each device was tested on known low, normal, and elevated samples. Actual and absolute deviations from the reference standard demonstrate that the Accuchek bG and Glucoscan 2000 monitors provide relatively unbiased estimates of blood glucose, whereas the Glucokey, Glucochek II, Glucometer II, and Trendsmeter generally underestimate the true values. The Diascan and Accuchek II monitors, in a separate evaluation, demonstrated acceptable accuracy and precision. We conclude that the Accuchek bG and Glucoscan 2000 statistically are the most accurate and precise HMBGs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.