Background
Covered stent correction of sinus venosus ASDs (SVASD) is a relatively new technique. Challenges include anchoring a sufficiently long stent in a nonstenotic superior vena cava (SVC) and expanding the stent at the wider SVC‐RA junction without obstructing the anomalous right upper pulmonary vein (RUPV). The 10‐zig covered Cheatham‐platinum (CCP) stent has the advantage of being available in lengths of 5–11 cm and dilatable to 34 mm in diameter.
Methods
An international registry reviewed the outcomes of 10‐zig CCP stents in 75 patients aged 11.4–75.9 years (median 45.4) from March 2016. Additional stents were used to anchor the stent in the SVC or close residual shunts in 33/75. An additional stent was placed in 4/5 (80%) with 5/5.5 cm CCPs, 18/29 (62%) with 6 cm CCPs, 5/18 (28%) with 7 cm CCPs, 5/22 (23%) with 7.5/8 cm CCPs and 0/1 with an 11 cm CCP. A “protective” balloon catheter was inflated in the RUPV in 17.
Results
Early stent embolization in two patients required surgical removal and defect repair and tamponade was drained in one patient. The CT at 3 months showed occlusion of the RUPV in one patient. Follow up is from 2 months to 5.1 years (median 1.8 years). QP:QS has reduced from 2.5 ± 0.5 to 1.2 ± 0.36 (p < .001) and RVEDVi from 149.1 ± 35.4 to 95.6 ± 21.43 ml/m2 (p < .001).
Conclusions
Ten‐zig CCPs of 7–8 cm appear to provide reliable SVASD closure with a low requirement for additional stents. Careful selection of patients and meticulous attention to detail is required to avoid complications.
AFR implantation was feasible and safe in all patients with PAH. There was a significant improvement of symptoms, six-minute walk distance, cardiac index and systemic oxygen transport. The device maintained patency in short-term follow-up and the resultant hypoxia was tolerated well.
Three-dimensional (3D) printing is an emerging technology aiding diagnostics, education, and interventional, and surgical planning in congenital heart disease (CHD). Three-dimensional printing has been derived from computed tomography, cardiac magnetic resonance, and 3D echocardiography. However, individually the imaging modalities may not provide adequate visualization of complex CHD. The integration of the strengths of two or more imaging modalities has the potential to enhance visualization of cardiac pathomorphology. We describe the feasibility of hybrid 3D printing from two imaging modalities in a patient with congenitally corrected transposition of the great arteries (L-TGA). Hybrid 3D printing may be useful as an additional tool for cardiologists and cardiothoracic surgeons in planning interventions in children and adults with CHD.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.