Stent placement for coarctation of aorta is an effective treatment option, though it remains a technically challenging procedure. Technical and aortic complications have decreased over the past 3 years due to, in part, improvement in balloon and stent design. Improvement in our ability to assess aortic wall compliance is essential prior to placement of ISs in older patients with coarctation of the aorta.
A coronary arterial fistula is a connection between one or more of the coronary arteries and a cardiac chamber or great vessel. This is a rare defect and usually occurs in isolation. Its exact incidence is unknown.
Seven patients with a coronary artery fistula underwent percutaneous transcatheter embolization (five were male and two female; the age range was 2 to 67 years [median 17]). Three patients were symptomatic. The left to right shunt ranged from 1.6 to 2.6:1. In six patients, the fistula was an isolated congenital anomaly; in one, it was acquired. The fistula arose from branches of the left (n = 5) and right (n = 2) coronary arteries and drained to the right ventricle (n = 2), right atrium (n = 2), coronary sinus (n = 1), pulmonary artery (n = 1) and a bronchial artery (n = 1). Different embolization techniques were used to occlude eight feeding arteries. The embolization materials included a detachable balloon (n = 3), coaxial embolization with platinum microcoils (n = 3), a combination of detachable balloon and microcoil (n = 1) and standard steel coils (n = 1). Satisfactory occlusion was achieved in six patients. In one case, the valve of the detachable balloon was damaged, resulting in early balloon deflation and a residual fistula. There were no associated complications in any patient. Follow-up investigation by Doppler ultrasound or coronary angiography 4 months to 4 years later showed that permanent occlusion was achieved in all six patients in whom embolization was initially successful. Transcatheter embolization should be considered the treatment of choice for coronary artery fistulas.
Covered CP stents may be used as the therapy of choice in patients with complications after CoA repairs, whereas they provide a safe alternative to conventional stenting in patients with severe and complex CoA lesions or advanced age.
Abnormalities were observed at intermediate follow-up following IS placement for treatment of native and recurrent coarctation of the aorta. Not exceeding a balloon:coarctation ratio of 3.5 and avoidance of prestent angioplasty decreased the likelihood of encountering an abnormal follow-up imaging study in patients undergoing intravascular stent placement for the treatment of coarctation of the aorta. We recommend IAI for all patients undergoing IS placement for treatment of CoA.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.