The objective of this work is to present commissioning procedures to clinically implement a three‐dimensional (3D), image‐based, treatment‐planning system (TPS) for high‐dose‐rate (HDR) brachytherapy (BT) for gynecological (GYN) cancer. The physical dimensions of the GYN applicators and their values in the virtual applicator library were varied by 0.4 mm of their nominal values. Reconstruction uncertainties of the titanium tandem and ovoids (T&O) were less than 0.4 mm on CT phantom studies and on average between 0.8‐1.0 mm on MRI when compared with X‐rays. In‐house software, HDRCalculator, was developed to check HDR plan parameters such as independently verifying active tandem or cylinder probe length and ovoid or cylinder size, source calibration and treatment date, and differences between average Point A dose and prescription dose. Dose‐volume histograms were validated using another independent TPS. Comprehensive procedures to commission volume optimization algorithms and process in 3D image‐based planning were presented. For the difference between line and volume optimizations, the average absolute differences as a percentage were 1.4% for total reference air KERMA (TRAK) and 1.1% for Point A dose. Volume optimization consistency tests between versions resulted in average absolute differences in 0.2% for TRAK and 0.9 s (0.2%) for total treatment time. The data revealed that the optimizer should run for at least 1 min in order to avoid more than 0.6% dwell time changes. For clinical GYN T&O cases, three different volume optimization techniques (graphical optimization, pure inverse planning, and hybrid inverse optimization) were investigated by comparing them against a conventional Point A technique. End‐to‐end testing was performed using a T&O phantom to ensure no errors or inconsistencies occurred from imaging through to planning and delivery. The proposed commissioning procedures provide a clinically safe implementation technique for 3D image‐based TPS for HDR BT for GYN cancer.PACS number(s): 87.55.D‐
PurposeTo evaluate conventional brachytherapy (BT) plans using dose-volume parameters and high resolution (3 Tesla) MRI datasets, and to quantify dosimetric benefits and limitations when MRI-guided, conformal BT (MRIG-CBT) plans are generated.Material and methodsFifty-five clinical high-dose-rate BT plans from 14 cervical cancer patients were retrospectively studied. All conventional plans were created using MRI with titanium tandem-and-ovoid applicator (T&O) for delivery. For each conventional plan, a MRIG-CBT plan was retrospectively generated using hybrid inverse optimization. Three categories of high risk (HR)-CTV were considered based on volume: non-bulky (< 20 cc), low-bulky (> 20 cc and < 40 cc) and bulky (≥ 40 cc). Dose-volume metrics of D90 of HR-CTV and D2cc and D0.1cc of rectum, bladder, and sigmoid colon were analyzed.ResultsTumor coverage (HR-CTV D90) of the conventional plans was considerably affected by the HR-CTV size. Sixteen percent of the plans covered HR-CTV D90 with the prescription dose within 5%. At least one OAR had D2cc values over the GEC-ESTRO recommended limits in 52.7% of the conventional plans. MRIG-CBT plans showed improved target coverage for HR-CTV D90 of 98 and 97% of the prescribed dose for non-bulky and low-bulky tumors, respectively. No MRIG-CBT plans surpassed the D2cc limits of any OAR. Only small improvements (D90 of 80%) were found for large targets (> 40 cc) when using T&O applicator approach.ConclusionsMRIG-CBT plans displayed considerable improvement for tumor coverage and OAR sparing over conventional treatment. When the HR-CTV volume exceeded 40 cc, its improvements were diminished when using a conventional intracavitary applicator.
In a previous article, we presented development and verification of an integral transport equation-based deterministic algorithm for computing three-dimensional brachytherapy dose distributions. Recently, we have included fluorescence radiation physics and parallel computation to the standing algorithms so that we can compute dose distributions for a large set of seeds without resorting to the superposition methods. The introduction of parallel computing capability provided a means to compute the dose distribution for multiple seeds in a simultaneous manner. This provided a way to study strong heterogeneity and shadow effects induced by the presence of multiple seeds in an interstitial brachytherapy implant. This article presents the algorithm for computing fluorescence radiation, algorithm for parallel computing, and display results for an 81-seed implant that has a perfect and imperfect lattice. The dosimetry data for a single model 6711 seeds is presented for verification and heterogeneity factor computations using simultaneous and superposition techniques are presented.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.