Buprenorphine is a potent opioid analgesic used in the treatment of moderate to severe pain. At higher doses, it has demonstrated potential for treating heroin dependence. This study was undertaken to investigate buprenorphine pharmacokinetics by different routes of administration at dosages approximating those used in opioid-dependence studies. Six healthy men who were nondependent but who had a history of heroin use were administered buprenorphine in a crossover design study by intravenous (1.2 mg), sublingual (4.0 mg), and buccal (4.0 mg) routes of administration. Plasma samples were collected up to 96 h and assayed for buprenorphine and norbuprenorphine by negative chemical ionization tandem mass spectrometry. Plasma concentrations of buprenorphine and norbuprenorphine were analyzed by nonlinear regression analysis with standard noncompartmental methods. Buprenorphine biovailability by the sublingual and buccal routes was estimated as 51.4% and 27.8%, respectively, although there was considerable interindividual variability by both routes of administration. The terminal elimination half-lives were longer for the sublingual and buccal routes than for the intravenous route. The extended elimination half-lives may be due to a shallow depot effect involving sequestration of buprenorphine in the oral mucosa. Norbuprenorphine mean peak plasma concentrations were less than 1 ng/mL and were highly variable among different routes of administration and individuals. The terminal elimination half-life of norbuprenorphine was longer than buprenorphine.
A death involving abuse of propylhexedrine and mitragynine is reported. Propylhexedrine is a potent α-adrenergic sympathomimetic amine found in nasal decongestant inhalers. The decedent was found dead in his living quarters with no signs of physical trauma. Analysis of his computer showed information on kratom, a plant that contains mitragynine, which produces opiumlike effects at high doses and stimulant effects at low doses, and a procedure to concentrate propylhexedrine from over-the-counter inhalers. Toxicology results revealed the presence of 1.7 mg/L propylhexedrine and 0.39 mg/L mitragynine in his blood. Both drugs, as well as acetaminophen, morphine, and promethazine, were detected in the urine. Quantitative results were achieved by gas chromatography-mass spectrometry monitoring selected ions for the propylhexedrine heptafluorobutyryl derivative. Liquid chromatography-tandem mass spectrometry in multiple reactions monitoring mode was used to obtain quantitative results for mitragynine. The cause of death was ruled propylhexedrine toxicity, and the manner of death was ruled accidental. Mitragynine may have contributed as well, but as there are no published data for drug concentrations, the medical examiner did not include mitragynine toxicity in the cause of death. This is the first known publication of a case report involving propylhexedrine and mitragynine.
Synthetic cannabinoids emerged on the designer drug market in recent years due to their ability to produce cannabis-like effects without the risk of detection by traditional drug testing techniques such as immunoassay and gas chromatography-mass spectrometry. As government agencies work to schedule existing synthetic cannabinoids, new, unregulated and structurally diverse compounds continue to be developed and sold. Synthetic cannabinoids undergo extensive metabolic conversion. Consequently, both blood and urine specimens may play an important role in the forensic analysis of synthetic cannabinoids. It has been observed that structurally similar synthetic cannabinoids follow common metabolic pathways, which often produce metabolites with similar metabolic transformations. Presented are two validated quantitative methods for extracting and identifying 15 parent synthetic cannabinoids in blood, 17 synthetic cannabinoid metabolites in urine and the qualitative identification of 2 additional parent compounds. The linear range for most synthetic cannabinoid compounds monitored was 0.1-10 ng/mL with the limit of detection between 0.01 and 0.5 ng/mL. Selectivity, specificity, accuracy, precision, recovery and matrix effect were also examined and determined to be acceptable for each compound. The validated methods were used to analyze a compilation of synthetic cannabinoid investigative cases where both blood and urine specimens were submitted. The study suggests a strong correlation between the metabolites detected in urine and the parent compounds found in blood.
The Department of Defense (DoD) operates six forensic urine drug-testing laboratories that screen close to 5 million urine samples for amphetamines yearly. Recently, the DoD laboratories have observed a significant decrease in the confirmation rates for amphetamines because of specimens screening positive by two separate immunoassays and confirming negative by gas chromatography-mass spectrometry (GC-MS). Previous studies conducted by the Division of Forensic Toxicology, Armed Force Institute of Pathology (AFIP) utilizing a GC-MS basic drug screen and a designer drug screen revealed no common compound or compound classes as to the cause of the immunoassay-positive results. Additional information obtained from an immunoassay vendor suggested the anorectic compound dimethylamylamine (DMAA) may be the cause of the false-positive screens. An additional 134 false-positive samples were received and analyzed using liquid chromatography-tandem mass spectrometry (LC-MS-MS) for DMAA. LC-MS-MS analysis revealed the presence of DMAA in 92.3% of the false-positive samples at a concentration of approximately 6.0 mg/L DMAA, causing a positive screen on both immunoassay kits.
A case is presented of a 19-year-old white male who was found dead in bed by a friend. While no anatomic cause of death was observed at autopsy, toxicological analysis of his blood identified AH-7921, a synthetic opioid. AH-7921 was isolated by liquid-liquid extraction into n-butyl chloride from alkalinized samples. Extracts were analyzed and quantified by gas chromatography mass spectrometry in selected ion monitoring mode. The heart blood had an AH-7921 concentration of 3.9 mg/L and the peripheral blood concentration was 9.1 mg/L. In addition to the blood, all submitted postmortem specimens including urine, liver, kidney, spleen, heart, lung, brain, bile and stomach content were quantified. The following concentrations of AH-7921 were reported: 6.0 mg/L in urine, 26 mg/kg in liver, 7.2 mg/kg in kidney, 8.0 mg/kg in spleen, 5.1 mg/kg in heart, 21 mg/kg in lung, 7.7 mg/kg in brain, 17 mg/L in bile and 120 mg/125 mL in the stomach content. The medical examiner reported that the cause of death was opioid intoxication and the manner of death was accident.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.