Abstract. We describe a method of evaluating systematic errors in measurements of total column dry-air mole fractions of CO 2 (X CO 2 ) from space, and we illustrate the method by applying it to the v2.8 Atmospheric CO 2 Observations from Space retrievals of the Greenhouse Gases Observing Satellite (ACOS-GOSAT) measurements over land. The approach exploits the lack of large gradients in X CO 2 south of 25 • S to identify large-scale offsets and other biases in the ACOS-GOSAT data with several retrieval parameters and errors in instrument calibration. We demonstrate the effectiveness of the method by comparing the ACOS-GOSAT data in the Northern Hemisphere with ground truth provided by the Total Carbon Column Observing Network (TCCON). We use Correspondence to: D. Wunch (dwunch@gps.caltech.edu) the observed correlation between free-tropospheric potential temperature and X CO 2 in the Northern Hemisphere to define a dynamically informed coincidence criterion between the ground-based TCCON measurements and the ACOS-GOSAT measurements. We illustrate that this approach provides larger sample sizes, hence giving a more robust comparison than one that simply uses time, latitude and longitude criteria. Our results show that the agreement with the TC-CON data improves after accounting for the systematic errors, but that extrapolation to conditions found outside the region south of 25 • S may be problematic (e.g., high airmasses, large surface pressure biases, M-gain, measurements made over ocean). A preliminary evaluation of the improved v2.9 ACOS-GOSAT data is also discussed.
Abstract. The column-averaged dry-air mole fractions of carbon dioxide and methane (XCO2 and XCH4) have been retrieved from Greenhouse gases Observing SATellite (GOSAT) Short-Wavelength InfraRed (SWIR) observations and released as a SWIR L2 product from the National Institute for Environmental Studies (NIES). XCO2 and XCH4 retrieved using the version 01.xx retrieval algorithm showed large negative biases and standard deviations (−8.85 and 4.75 ppm for XCO2 and −20.4 and 18.9 ppb for XCH4, respectively) compared with data of the Total Carbon Column Observing Network (TCCON). Multiple reasons for these error characteristics (e.g., solar irradiance database, handling of aerosol scattering) are identified and corrected in a revised version of the retrieval algorithm (version 02.xx). The improved retrieval algorithm shows much smaller biases and standard deviations (−1.48 and 2.09 ppm for XCO2 and −5.9 and 12.6 ppb for XCH4, respectively) than the version 01.xx. Also, the number of post-screened measurements is increased, especially at northern mid- and high-latitudinal areas.
Abstract. NASA's Orbiting Carbon Observatory-2 (OCO-2) has been measuring carbon dioxide column-averaged dryair mole fraction, X CO 2 , in the Earth's atmosphere for over 2 years. In this paper, we describe the comparisons between the first major release of the OCO-2 retrieval algorithm (B7r) and X CO 2 from OCO-2's primary ground-based validation network: the Total Carbon Column Observing Network (TC-CON). The OCO-2 X CO 2 retrievals, after filtering and bias correction, agree well when aggregated around and coincident with TCCON data in nadir, glint, and target observation modes, with absolute median differences less than 0.4 ppm and RMS differences less than 1.5 ppm. After bias correction, residual biases remain. These biases appear to depend on latitude, surface properties, and scattering by aerosols. It is thus crucial to continue measurement comparisons with TCCON to monitor and evaluate the OCO-2 X CO 2 data quality throughout its mission.
We describe a method of evaluating systematic errors in measurements of total column dry-air mole fractions of CO2 (XCO2) from space, and we illustrate the method by applying the method to the Atmospheric CO2 Observations from Space retrievals of the Greenhouse Gases Observing Satellite (ACOS-GOSAT) v2.8 data. The approach exploits the lack of large gradients in XCO2 south of 25° S to identify large-scale offsets and other biases in the ACOS-GOSAT data with several retrieval parameters and errors in instrument calibration. We demonstrate the effectiveness of the method by comparing the ACOS-GOSAT data in the Northern Hemisphere with ground truth provided by the Total Carbon Column Observing Network (TCCON). We use the correlation between free-tropospheric temperature and XCO2 in the Northern Hemisphere to define a dynamically informed coincidence criterion between the ground-based TCCON measurements and the ACOS-GOSAT measurements. We illustrate that this approach provides larger sample sizes, hence giving a more robust comparison than one that simply uses time, latitude and longitude criteria. Our results show that the agreement with the TCCON data improves after accounting for the systematic errors
Abstract. The Optical Spectrograph and Infra-Red Imager System (OSIRIS) and the Atmospheric Chemistry Experiment (ACE) have been taking measurements from space since 2001 and 2003, respectively. This paper presents intercomparisons between ozone and NO 2 measured by the ACE and OSIRIS satellite instruments and by groundbased instruments at the Polar Environment Atmospheric Research Laboratory (PEARL), which is located at Eureka, Canada (80 • N, 86 • W) and is operated by the Canadian Network for the Detection of Atmospheric Change (CANDAC). The ground-based instruments included in this study are four zenith-sky differential optical absorption spectroscopy (DOAS) instruments, one Bruker Fourier transform infrared spectrometer (FTIR) and four Brewer spectrophotometers.Ozone total columns measured by the DOAS instruments were retrieved using new Network for the Detection of Atmospheric Composition Change (NDACC) guidelines and agree to within 3.2 %. The DOAS ozone columns agree with the Brewer spectrophotometers with mean relative differences that are smaller than 1.5 %. This suggests that for these instruments the new NDACC data guidelines were successful in producing a homogenous and accurate ozone dataset at 80 • N. Satellite 14-52 km ozone and 17-40 km NO 2 partial columns within 500 km of PEARL were calculated for ACE-FTS Version 2.2 (v2.2) plus updates, ACE- C. Adams et al.: Validation of ACE and OSIRISand Optimal Estimation v3.0 NO 2 data products. The new ACE-FTS v3.0 and the validated ACE-FTS v2.2 partial columns are nearly identical, with mean relative differences of 0.0 ± 0.2 % and −0.2 ± 0.1 % for v2.2 minus v3.0 ozone and NO 2 , respectively. Ozone columns were constructed from 14-52 km satellite and 0-14 km ozonesonde partial columns and compared with the ground-based total column measurements. The satellite-plus-sonde measurements agree with the ground-based ozone total columns with mean relative differences of 0.1-7.3 %. For NO 2 , partial columns from 17 km upward were scaled to noon using a photochemical model. Mean relative differences between OSIRIS, ACE-FTS and ground-based NO 2 measurements do not exceed 20 %. ACE-MAESTRO measures more NO 2 than the other instruments, with mean relative differences of 25-52 %. Seasonal variation in the differences between NO 2 partial columns is observed, suggesting that there are systematic errors in the measurements and/or the photochemical model corrections. For ozone spring-time measurements, additional coincidence criteria based on stratospheric temperature and the location of the polar vortex were found to improve agreement between some of the instruments. For ACE-FTS v2.2 minus Bruker FTIR, the 2007-2009 spring-time mean relative difference improved from −5.0 ± 0.4 % to −3.1 ± 0.8 % with the dynamical selection criteria. This was the largest improvement, likely because both instruments measure direct sunlight and therefore have well-characterized lines-of-sight compared with scattered sunlight measurements. For NO 2 , the addition of a ±1 • latitude co...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.