The mobility of molecules on a solid surface plays a key role in diverse phenomena such as friction and self-assembly and in surface-based technologies like heterogeneous catalysis and molecular targeting. To understand and control these surface processes, a universally applicable model of surface transport at solid-liquid interfaces is needed. However, unlike diffusion at a solid-gas interface, little is known about the mechanisms of diffusion at a solid-liquid interface. Using single-molecule tracking at a solid-liquid interface, we found that a diverse set of molecules underwent intermittent random walks with non-Gaussian displacements. This contrasts with the normal random walk and Gaussian statistics that are commonly assumed for molecular surface diffusion. The molecules became temporarily immobilized for random waiting times between surface displacements produced by excursions through the bulk fluid. A common power-law distribution of waiting times indicated a spectrum of binding energies. We propose that intermittent hopping is universal to molecular surface diffusion at a solid-liquid interface.
The dynamics of polymers adsorbed to a solid surface are important in thin-film formation, adhesion phenomena, and biosensing applications, but they are still poorly understood. Here we present tracking data that follow the dynamics of isolated poly(ethylene glycol) chains adsorbed at a hydrophobic solid-liquid interface. We found that molecules moved on the surface via a continuous-time random walk mechanism, where periods of immobilization were punctuated by desorption-mediated jumps. The dependence of the surface mobility on molecular weight (2, 5, 10, 20, and 40 kg/mol were investigated) suggested that surface-adsorbed polymers maintained effectively three-dimensional surface conformations. These results indicate that polymer surface diffusion, rather than occurring in the two dimensions of the interface, is dominated by a three-dimensional mechanism that leads to large surface displacements and significant bulk-surface coupling.
The efficiency of chromatographic separations decreases markedly when peaks exhibit asymmetry (e.g., "peak tailing"). Theoretically, these effects can arise from heterogeneous adsorption kinetics. To investigate the nature and consequences of such heterogeneity, we used a combination of single-molecule imaging and reversed-phase liquid chromatography (RPLC). In both single-molecule and macroscopic RPLC experiments, the stationary phase was hydrophobic end-capped (trimethylsilyl-functionalized) silica, which we exposed to different methanol/water solutions (50%-62% methanol), containing a fluorescent fatty acid analyte. Super-resolution maps based on single-molecule observations revealed rare, strong adsorption sites with activity that varied significantly with methanol concentration. The adsorption and desorption kinetics on the strong sites were heterogeneous and positively correlated, suggesting a broad underlying distribution of site binding energies. Adsorption equilibrium on the strong sites was more sensitive to solution conditions than overall retention measured in RPLC experiments, suggesting that the effect of strong sites on the overall adsorption kinetics should change with solution conditions. Interestingly, in RPLC experiments, peak tailing had a nonmonotonic dependence on methanol concentration within the range studied. Using the stochastic model of chromatography, we showed quantitatively that our single-molecule kinetic results were consistent with this macroscopic trend. This approach to identifying and quantifying adsorption sites should be useful for designing better chromatographic separations and for identifying the role of heterogeneous surface chemistry in molecular dynamics.
Although polymeric membranes are widely used in the purification of protein pharmaceuticals, interactions between biomolecules and membrane surfaces can lead to reduced membrane performance and damage to the product. In this study, single-molecule fluorescence microscopy provided direct observation of bovine serum albumin (BSA) and human monoclonal antibody (IgG) dynamics at the interface between aqueous buffer and polymeric membrane materials including regenerated cellulose and unmodified poly(ether sulfone) (PES) blended with either polyvinylpyrrolidone (PVP), polyvinyl acetate-co-polyvinylpyrrolidone (PVAc-PVP), or polyethylene glycol methacrylate (PEGM) before casting. These polymer surfaces were compared with model surfaces composed of hydrophilic bare fused silica and hydrophobic trimethylsilane-coated fused silica. At extremely dilute protein concentrations (10(-3)-10(-7) mg/mL), protein surface exchange was highly dynamic with protein monomers desorbing from the surface within ∼1 s after adsorption. Protein oligomers (e.g., nonspecific dimers, trimers, or larger aggregates), although less common, remained on the surface for 5 times longer than monomers. Using newly developed super-resolution methods, we could localize adsorption sites with ∼50 nm resolution and quantify the spatial heterogeneity of the various surfaces. On a small anomalous subset of the adsorption sites, proteins adsorbed preferentially and tended to reside for significantly longer times (i.e., on "strong" sites). Proteins resided for shorter times overall on surfaces that were more homogeneous and exhibited fewer strong sites (e.g., PVAc-PVP/PES). We propose that strong surface sites may nucleate protein aggregation, initiated preferentially by protein oligomers, and accelerate ultrafiltration membrane fouling. At high protein concentrations (0.3-1.0 mg/mL), fewer strong adsorption sites were observed, and surface residence times were reduced. This suggests that at high concentrations, adsorbed proteins block strong sites from further protein adsorption. Importantly, this demonstrates that strong binding sites can be modified by changing solution conditions. Membrane surfaces are intrinsically heterogeneous; by employing single-molecule techniques, we have provided a new framework for understanding protein interactions with such surfaces.
Polymers are found near surfaces and interfaces in a wide range of chemical and biological systems, and the structure and dynamics of adsorbed polymer chains have been the subject of intense interest for decades. While polymer structure is often inferred from dynamic measurements in bulk solution, this approach has proven difficult to implement at interfaces, and the understanding of interfacial polymer conformation remains elusive. Here we used single-molecule tracking to study the interfacial diffusion of isolated poly(ethylene glycol) molecules at oil-water interfaces. Compared to diffusion in dilute aqueous solution, which exhibited the expected dependence of the diffusion coefficient (D) upon molecular weight (M) of D ∼ M(-1/2) for a Gaussian chain, the behavior at the interface was approximately D ∼ M(-2/3), suggesting a significantly more expanded polymer conformation, despite the fact that the oil was a poor solvent for the polymer. Interestingly, this scaling remained virtually unchanged over a wide range of oil viscosity, despite the fact that at low viscosities the magnitude of the diffusion coefficient was consistent with expectations based on viscous drag (i.e., Stokes-Einstein diffusion), and for high viscosity oil, the interfacial mobility was much faster than expected and consistent with the type of intermittent hopping transport observed at the solid-liquid interface. The dependence on molecular weight, in both regimes, was consistent with results from both self-consistent field theory and previous Monte Carlo simulations, suggesting that an adsorbed polymer chain adopted a partially swollen (loop-train-tail) interfacial conformation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.