The study aimed to determine the associations of Peak Inspiratory Flow (PIF), inhalation technique and adherence with health status and exacerbations in participants with COPD using DPI maintenance therapy. This cross-sectional multi-country observational real-world study included COPD participants aged ≥40 years using a DPI for maintenance therapy. PIF was measured three times with the In-Check DIAL G16: (1) typical PIF at resistance of participant’s inhaler, (2) maximal PIF at resistance of participant’s inhaler, (3) maximal PIF at low resistance. Suboptimal PIF (sPIF) was defined as PIF lower than required for the device. Participants completed questionnaires on health status (Clinical COPD Questionnaire (CCQ)), adherence (Test of Adherence to Inhalers (TAI)) and exacerbations. Inhalation technique was assessed by standardised evaluation of video recordings. Complete data were available from 1434 participants (50.1% female, mean age 69.2 years). GOLD stage was available for 801 participants: GOLD stage I (23.6%), II (54.9%), III (17.4%) and IV (4.1%)). Of all participants, 29% had a sPIF, and 16% were shown able to generate an optimal PIF but failed to do so. sPIF was significantly associated with worse health status (0.226 (95% CI 0.107–0.346), worse units on CCQ; p = 0.001). The errors ‘teeth and lips sealed around mouthpiece’, ‘breathe in’, and ‘breathe out calmly after inhalation’ were related to health status. Adherence was not associated with health status. After correcting for multiple testing, no significant association was found with moderate or severe exacerbations in the last 12 months. To conclude, sPIF is associated with poorer health status. This study demonstrates the importance of PIF assessment in DPI inhalation therapy. Healthcare professionals should consider selecting appropriate inhalers in cases of sPIF.
Purpose To assess the relationship between suboptimal Peak Inspiratory Flow (sPIF), inhalation technique errors, and non-adherence, with Healthcare Resource Utilisation (HCRU) in Chronic Obstructive Pulmonary Disease (COPD) patients receiving maintenance therapy via a Dry Powder Inhaler (DPI). Patients and methods The cross-sectional, multi-country PIFotal study included 1434 COPD patients (≥40 years) using a DPI for maintenance therapy. PIF was measured with the In-Check DIAL G16, and sPIF was defined as a typical PIF lower than required for the device. Inhalation technique was assessed by standardised evaluation of video recordings and grouped into 10 steps. Patients completed the “Test of Adherence to Inhalers” questionnaire. HCRU was operationalised as COPD-related costs for primary healthcare, secondary healthcare, medication, and total COPD-related costs in a 1-year period. Results Participants with sPIF had higher medication costs compared with those with optimal PIF (cost ratio [CR]: 1.07, 95% CI [1.01, 1.14]). Multiple inhalation technique errors were associated with increased HCRU. Specifically, “insufficient inspiratory effort” with higher secondary healthcare costs (CR: 2.20, 95% CI [1.37, 3.54]) and higher total COPD-related costs (CR: 1.16, 95% CI 1.03–1.31). “no breath-hold following the inhalation manoeuvre (<6 s)” with higher medication costs (CR: 1.08, 95% CI [1.02, 1.15]) and total COPD-related costs (CR 1.17, 95% CI [1.07, 1.28]), and “not breathing out calmly after inhalation” with higher medication costs (CR: 1.19, 95% CI [1.04, 1.37]). Non-adherence was not significantly associated with HCRU. Conclusion sPIF and inhalation technique errors were associated with higher COPD-related healthcare utilisation and costs in COPD patients on DPI maintenance therapy.
Over 1400 patients using dry powder inhalers (DPIs) to deliver COPD maintenance therapies were recruited across Europe and Australia. Their peak inspiratory flow (PIF) was measured, inhaler technique was observed, and adherence to treatment assessed. From relating the findings with patient health status, and thereby identifying critical errors, key clinical recommendations for primary care clinicians were determined, namely – measure PIF before prescribing a DPI to ensure inhalation manoeuvre ability is well-matched with the device. Some patients could benefit from inhalation training whereas others should have their DPI changed for one better suited to their inspiratory ability or alternatively be prescribed an active device (such as a soft mist inhaler or pressurized metered dose inhaler). Observing the inhalation technique was valuable however this misses suboptimal PIF (approaching one fourth of patients with a satisfactory observed manoeuvre had a suboptimal PIF for their DPI). Assess adherence as deliberate non-adherence can point to a mismatch between a patient and their inhaler (deliberate non-adherence was significantly associated with PIFs below the minimum for the DPI). In-person observation of inhalation technique was found to be inferior to video rating based on device-specific checklists. Where video assessments are not possible, observation training for healthcare professionals would therefore be valuable particularly to improve the ability to identify the critical errors associated with health status namely ‘teeth and lips sealed around mouthpiece’, ‘breathe in’ and ‘breathing out calmly after inhalation’. However, it is recommended that observation alone should not replace PIF measurement in the DPI selection process.Trial registration:https://clinicaltrials.gov/ct2/show/NCT04532853.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.