Polymer Flooding has become one of the most implemented EOR techniques, due to three factors: First, Polymer flooding has expanded the range of the screening criteria parameters. Second, this EOR method is more effective than water injection, while handling water management issues in high water-cut reservoirs. Nevertheless, polymer retention can turn a viable technical project into an uneconomical one. Polymer loss due to retention is an inevitable phenomenon, which happens during injection processes. The development of experimental analysis aiming to minimize or reduce polymer loss from the displacing fluid bank is beneficial to broaden the application of this CEOR method. This experimental work evaluated the injection schemes aiming to reduce polymer retention in porous media. The approach consisted of injecting less-concentrated polymer banks followed for the main polymer bank designed for mobility control. An experimental methodology to quantify polymer retention due to each injected polymer bank, cumulative polymer retention, resistance factor, residual resistance factor and inaccessible pore volume (IPV) was developed. The measurement process was based on the injection of 20 PV polymer banks at a constant flow rate of 1ml/min at 25°C, separated by 30 PV brine banks. Two HPAM with molecular weights of 6-8 million and 20 million Daltons using 350mD and 5000 mD sandstone cores were tested, respectively. The HPAM solutions considering a Colombian field (0.7% NaCl) and seawater (3.5% TDS) salinities were prepared. All rock samples were previously submitted to the injection of 50 PV for preventing fines migration. Two injection schemes with variable polymer concentrations were performed: The first one in which the polymer concentration increased in each successive bank, and the second one in which the concentration decreased. HPAM concentration solutions from 50 ppm to 2000 ppm were sequentially used in both injection schemes. By comparing the results of these two schemes, the effect of the injection of the less-concentrated polymer solutions was evaluated. For the increasing concentration experiments, cumulative retention values of 175.7 μg/g and 58.9 μg/g were calculated for the low-molecular weight polymer and the high-molecular weight polymer, respectively. While comparing with decreasing concentration experiments, for the high-molecular weight HPAM a 19% of retention reduction was evidenced, but no retention reduction was observed for the low-molecular weight one. The results indicate that different retention mechanisms are strongly dependents on the absolute permeability of the samples. Additionally, IPV values of 0.5 PV and 0.25 PV were calculated using low and high permeability samples, respectively. There was no linear relation between the absolute permeability reduction and the polymer concentration of the first bank injected into the sample. The novelty of this work is to use sacrificial banks of less-concentrated HPAM solutions as a reducing retention agent for the polymer bank designed for mobility control.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.