IMPORTANCE An intraoperative higher level of positive end-expiratory positive pressure (PEEP) with alveolar recruitment maneuvers improves respiratory function in obese patients undergoing surgery, but the effect on clinical outcomes is uncertain. OBJECTIVE To determine whether a higher level of PEEP with alveolar recruitment maneuvers decreases postoperative pulmonary complications in obese patients undergoing surgery compared with a lower level of PEEP. DESIGN, SETTING, AND PARTICIPANTS Randomized clinical trial of 2013 adults with body mass indices of 35 or greater and substantial risk for postoperative pulmonary complications who were undergoing noncardiac, nonneurological surgery under general anesthesia. The trial was conducted at 77 sites in 23 countries from July 2014-February 2018; final follow-up: May 2018. INTERVENTIONS Patients were randomized to the high level of PEEP group (n = 989), consisting of a PEEP level of 12 cm H 2 O with alveolar recruitment maneuvers (a stepwise increase of tidal volume and eventually PEEP) or to the low level of PEEP group (n = 987), consisting of a PEEP level of 4 cm H 2 O. All patients received volume-controlled ventilation with a tidal volume of 7 mL/kg of predicted body weight. MAIN OUTCOMES AND MEASURES The primary outcome was a composite of pulmonary complications within the first 5 postoperative days, including respiratory failure, acute respiratory distress syndrome, bronchospasm, new pulmonary infiltrates, pulmonary infection, aspiration pneumonitis, pleural effusion, atelectasis, cardiopulmonary edema, and pneumothorax. Among the 9 prespecified secondary outcomes, 3 were intraoperative complications, including hypoxemia (oxygen desaturation with SpO 2 Յ92% for >1 minute). RESULTS Among 2013 adults who were randomized, 1976 (98.2%) completed the trial (mean age, 48.8 years; 1381 [69.9%] women; 1778 [90.1%] underwent abdominal operations). In the intention-to-treat analysis, the primary outcome occurred in 211 of 989 patients (21.3%) in the high level of PEEP group compared with 233 of 987 patients (23.6%) in the low level of PEEP group (difference, −2.3% [95% CI, −5.9% to 1.4%]; risk ratio, 0.93 [95% CI, 0.83 to 1.04]; P = .23). Among the 9 prespecified secondary outcomes, 6 were not significantly different between the high and low level of PEEP groups, and 3 were significantly different, including fewer patients with hypoxemia (5.0% in the high level of PEEP group vs 13.6% in the low level of PEEP group; difference, −8.6% [95% CI, −11.1% to 6.1%]; P < .001). CONCLUSIONS AND RELEVANCE Among obese patients undergoing surgery under general anesthesia, an intraoperative mechanical ventilation strategy with a higher level of PEEP and alveolar recruitment maneuvers, compared with a strategy with a lower level of PEEP, did not reduce postoperative pulmonary complications.
Background Intraoperative burst-suppression is associated with postoperative delirium. Whether this association is causal remains unclear. Therefore, the authors investigated whether burst-suppression during cardiopulmonary bypass (CPB) mediates the effects of known delirium risk factors on postoperative delirium. Methods This was a retrospective cohort observational substudy of the Minimizing ICU [intensive care unit] Neurological Dysfunction with Dexmedetomidine-induced Sleep (MINDDS) trial. The authors analyzed data from patients more than 60 yr old undergoing cardiac surgery (n = 159). Univariate and multivariable regression analyses were performed to assess for associations and enable causal inference. Delirium risk factors were evaluated using the abbreviated Montreal Cognitive Assessment and Patient-Reported Outcomes Measurement Information System questionnaires for applied cognition, physical function, global health, sleep, and pain. The authors also analyzed electroencephalogram data (n = 141). Results The incidence of delirium in patients with CPB burst-suppression was 25% (15 of 60) compared with 6% (5 of 81) in patients without CPB burst-suppression. In univariate analyses, age (odds ratio, 1.08 [95% CI, 1.03 to 1.14]; P = 0.002), lowest CPB temperature (odds ratio, 0.79 [0.66 to 0.94]; P = 0.010), alpha power (odds ratio, 0.65 [0.54 to 0.80]; P < 0.001), and physical function (odds ratio, 0.95 [0.91 to 0.98]; P = 0.007) were associated with CPB burst-suppression. In separate univariate analyses, age (odds ratio, 1.09 [1.02 to 1.16]; P = 0.009), abbreviated Montreal Cognitive Assessment (odds ratio, 0.80 [0.66 to 0.97]; P = 0.024), alpha power (odds ratio, 0.75 [0.59 to 0.96]; P = 0.025), and CPB burst-suppression (odds ratio, 3.79 [1.5 to 9.6]; P = 0.005) were associated with delirium. However, only physical function (odds ratio, 0.96 [0.91 to 0.99]; P = 0.044), lowest CPB temperature (odds ratio, 0.73 [0.58 to 0.88]; P = 0.003), and electroencephalogram alpha power (odds ratio, 0.61 [0.47 to 0.76]; P < 0.001) were retained as predictors in the burst-suppression multivariable model. Burst-suppression (odds ratio, 4.1 [1.5 to 13.7]; P = 0.012) and age (odds ratio, 1.07 [0.99 to 1.15]; P = 0.090) were retained as predictors in the delirium multivariable model. Delirium was associated with decreased electroencephalogram power from 6.8 to 24.4 Hertz. Conclusions The inference from the present study is that CPB burst-suppression mediates the effects of physical function, lowest CPB temperature, and electroencephalogram alpha power on delirium. Editor’s Perspective What We Already Know about This Topic What This Article Tells Us That Is New
Understanding anesthetic mechanisms with the goal of producing anesthetic states with limited systemic side effects is a major objective of neuroscience research in anesthesiology. Coherent frontal alpha oscillations have been postulated as a mechanism of sevoflurane general anesthesia. This postulate remains unproven. Therefore, we performed a single-site, randomized, cross-over, high-density electroencephalogram study of sevoflurane and sevoflurane-plus-ketamine general anesthesia in 12 healthy subjects. Data were analyzed with multitaper spectral, global coherence, cross-frequency coupling, and phase-dependent methods. Our results suggest that coherent alpha oscillations are not fundamental for maintaining sevoflurane general anesthesia. Taken together, our results suggest that subanesthetic and general anesthetic sevoflurane brain states emerge from impaired information processing instantiated by a delta-higher frequency phase-amplitude coupling syntax. These results provide fundamental new insights into the neural circuit mechanisms of sevoflurane anesthesia and suggest that anesthetic states may be produced by extracranial perturbations that cause delta-higher frequency phase-amplitude interactions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.