In 10 patients with chronic pulmonary emphysema the distribution of ventilation within the lungs was assessed by a nitrogen washout and washin technique. Alveolar ventilation per minute per unit lung volume had a mean value of 5.0 in well ventilated alveoli and 0.19, or 1/26 as much, in poorly ventilated alveoli. Distribution of blood perfusion was estimated by a new method from these data and from O2 consumption and arterial O2 saturation. On the average, poorly ventilated alveoli which constituted 66% of lung volume were perfused by not more than 52% of the cardiac output. Thus poorly ventilated alveoli were underperfused by blood. Ventilation/perfusion ratios averaged 2.24 in well ventilated alveoli and 0.23 in poorly ventilated alveoli. Oxygen saturation averaged 85% in arterial blood and 97frac12% and 76%, respectively, in end-capillary blood leaving well and poorly ventilated alveoli. Inhomogeneity of this degree within the lung invalidates calculations of diffusing capacity based on any single mean PaOO2 and of alveolar ventilation based on identification of mean alveolar Pco2 with arterial blood Pco2. Submitted on March 25, 1960
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.