The arm length and the isolation in space enable the Laser Interferometer Space Antenna (LISA) to probe for signals unattainable on the ground, opening a window to the subhertz gravitational-wave universe. The coupling of unavoidable angular spacecraft jitter into the longitudinal displacement measurement, an effect known as tilt-to-length (TTL) coupling, is critical for realizing the required sensitivity of picometer/ √ Hz. An ultrastable interferometer test bed has been developed in order to investigate this issue and validate mitigation strategies in a setup representative of LISA and in this paper it is operated in the long-arm interferometer configuration. The test bed is fitted with a flat-top beam generator to simulate the beam received by a LISA spacecraft. We demonstrate a reduction of TTL coupling between this flattop beam and a Gaussian reference beam via the introduction of two-and four-lens imaging systems. TTL coupling factors below ±25 μm/rad for beam tilts within ±300 μrad are obtained by careful optimization of the system. Moreover, we show that the additional TTL coupling due to lateral-alignment errors of elements of the imaging system can be compensated by introducing lateral shifts of the detector and vice versa. These findings help validate the suitability of this noise-reduction technique for the LISA long-arm interferometer.
Inter satellite laser interferometry is a central component of future space-borne gravity instruments like LISA, eLISA, NGO and future geodesy missions. The inherently small laser wavelength allows to measure distance variations with extremely high precision by interfering a reference beam with a measurement beam. The readout of such interferometers is often based on tracking phasemeters, able to measure the phase of an incoming beatnote with high precision over a wide range of frequencies. The implementation of such phasemeters is based on all digital phase-locked loops, hosted in FPGAs. Here we present a precise model of an all digital phase locked loop that allows to design such a readout algorithm and we support our analysis by numerical performance measurements and experiments with analog signals.
Precision phase readout of optical beat note signals is one of the core techniques required for intersatellite laser interferometry. Future space based gravitational wave detectors like eLISA require such a readout over a wide range of MHz frequencies, due to orbit induced Doppler shifts, with a precision in the order of μrad/√Hz at frequencies between 0.1 mHz and 1 Hz. In this paper, we present phase readout systems, so-called phasemeters, that are able to achieve such precisions and we discuss various means that have been employed to reduce noise in the analogue circuit domain and during digitisation. We also discuss the influence of some non-linear noise sources in the analogue domain of such phasemeters. And finally, we present the performance that was achieved during testing of the elegant breadboard model of the LISA phasemeter, which was developed in the scope of a European Space Agency technology development activity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.