Thirty-seven consecutive free anterolateral thigh flaps in 36 patients were transferred for reconstruction of head and neck defects following cancer ablation between January of 1997 and June of 1998. The success rate was 97 percent (36 of 37), with one flap lost due to a twisted perforator. The anatomic variations and length of the vascular pedicle were investigated to obtain better knowledge of anatomy and to avoid several surgical pitfalls when it is used for head and neck reconstruction. The cutaneous perforators were always found and presented as musculocutaneous or septocutaneous perforators in this series of 37 anterolateral thigh flaps. They were classified into four types according to the perforator derivation and the direction in which it traversed the vastus lateralis muscle. In type I, vertical musculocutaneous perforators from the descending branch of the lateral circumflex femoral artery were found in 56.8 percent of cases (21 of 37), and they were 4.83 +/- 2.04 cm in length. In type II, horizontal musculocutaneous perforators from the transverse branch of the lateral circumflex femoral artery were found in 27.0 percent of cases (10 of 37), and they were 6.77 +/- 3.48 cm in length. In type III, vertical septocutaneous perforators from the descending branch of the lateral circumflex femoral artery were found in 10.8 percent of cases (4 of 37), and they were 3.60 +/- 1.47 cm in length. In type IV, horizontal septocutaneous perforators from the transverse branch of the lateral circumflex femoral artery were found in 5.4 percent of cases (2 of 37). They were 7.75 +/- 1.06 cm in length. The average length of vascular pedicle was 12.01 +/- 1.50 cm, and the arterial diameter was around 2.0 to 2.5 mm; two accompanying veins varied from 1.8 to 3.0 mm and were suitable for anastomosis with the neck vessels. Reconstruction of one-layer defect, external skin or intraoral lining, was carried out in 18 cases, through-and-through defect in 17 cases, and composite mandibular defect in two cases. With increasing knowledge of anatomy and refinements of surgical technique, the anterolateral thigh flap can be harvested safely to reconstruct complicated defects of head and neck following cancer ablation with only minimal donor-site morbidity.
The distally based anterolateral thigh flap has been used for coverage of soft-tissue defects of the knee and upper third of the leg. This flap is based on the septocutaneous or musculocutaneous perforators derived from the lateral circumflex femoral system. The purpose of this study was to examine the results of anatomical variations of the descending branch of the lateral circumflex femoral artery and the retrograde blood pressure of the descending branch of the lateral circumflex femoral artery so that the surgical technique for raising and transferring a distally based anterolateral thigh flap to the knee region could be improved. The authors have actually used this flap in three cases. In 11 thighs of six cadavers, the descending branch of the lateral circumflex femoral artery had a rather consistent connection with the lateral superior genicular artery or profunda femoral artery in the knee region. The pivot point, located at the distal portion of the vastus lateralis muscle, ranges from 3 to 10 cm above the knee. In their three cases, the maximal flap size was 7.0 x 16.0 cm and was harvested safely, without marginal necrosis. The mean pedicle length was 15.2 +/- 0.7 cm (range, 14.5 to 16 cm). The average proximal and distal retrograde blood pressure of the descending branch of the lateral circumflex femoral artery was also studied in another 11 patients, and the anterolateral thigh flap being used for reconstruction of head and neck defects showed 58.3 and 77.7 percent of proximal antegrade blood pressure, respectively. The advantages of this flap include a long pedicle length, a sufficient tissue supply, possible combination with fascia lata for tendon reconstruction, and favorable donor-site selection, without sacrifice of major vessels or muscles.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.