An intelligent rolling contact fatigue test equipment is developed, and the control methods are presented. For obtaining the slip accurately, the control method based on master-slave synchronization is proposed. For controlling the loads in high precision, the control method took into consideration the influence by two factors, displacement and the load. e nonlinear interference and excess torque in load control are effectively suppressed. Based on the SIMOTION D425 which is the Siemens integrated motion control system, the control system architecture of the intelligent rolling contact fatigue test equipment is constructed. e solutions of slip ratio and the experimental load controlled by these methods are satisfactory with the requirement of design precision. In the validation experiment, the load control accuracy is ±3%, the average error of load control is 1.77%, and the average error of slip control is 0.26%. e experiment results show the proposed control methods are feasible and effective.
Background Home-based resistance training offers an alternative to traditional, hospital-based or rehabilitation center-based resistance training and has attracted much attention recently. However, without the supervision of a therapist or the assistance of an exercise monitoring system, one of the biggest challenges of home-based resistance training is that the therapist may not know if the patient has performed the exercise as prescribed. A lack of objective measurements limits the ability of researchers to evaluate the outcome of exercise interventions and choose suitable training doses. Objective To create an automated and objective method for segmenting resistance force data into contraction phase-specific segments and calculate the repetition number and time-under-tension (TUT) during elbow flexor resistance training. A pilot study was conducted to evaluate the performance of the segmentation algorithm and to show the capability of the system in monitoring the compliance of patients to a prescribed training program in a practical resistance training setting. Methods Six subjects (three male and three female) volunteered to participate in a fatigue and recovery experiment (5 min intermittent submaximal contraction (ISC); 1 min rest; 2 min ISC). A custom-made resistance band was used to help subjects perform biceps curl resistance exercises and the resistance was recorded through a load cell. The maximum and minimum values of the force-derivative were obtained as distinguishing features and a segmentation algorithm was proposed to divide the biceps curl cycle into concentric, eccentric and isometric contraction, and rest phases. Two assessors, who were unfamiliar with the study, were recruited to manually pick the visually observed cut-off point between two contraction phases and the TUT was calculated and compared to evaluate performance of the segmentation algorithm. Results The segmentation algorithm was programmatically implemented and the repetition number and contraction-phase specific TUT were calculated. During isometric, the average TUT (3.75 ± 0.62 s) was longer than the prescribed 3 s, indicating that most subjects did not perform the exercise as prescribed. There was a good TUT agreement and contraction segment agreement between the proposed algorithm and the assessors. Conclusion The good agreement in TUT between the proposed algorithm and the assessors indicates that the proposed algorithm can correctly segment the contraction into contraction phase-specific parts, thereby providing clinicians and researchers with an automated and objective method for quantifying home-based elbow flexor resistance training. The instrument is easy to use and cheap, and the segmentation algorithm is programmatically implemented, indicating good application prospect of the method in a practical setting.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.