A robust high-throughput method was refined to extract three growth-promoting antibiotics, tylosin (TYL), chlortetracycline (CTC), and monensin (MON), from soil. Analysis was performed by electrospray liquid chromatography tandem mass spectrometry. Soil dissipation rate studies were performed in a farm field soil for antibiotics applied with and without manure. Tylosin, CTC, and MON followed first-order dissipation kinetics with half-lives of 4.5, 24, and 3.3 d, respectively, with the addition of manure and 6.1, 21, and 3.8 d, respectively, without manure. Manure application significantly increased TYL dissipation rate, perhaps because of the introduced microbial flora, but had no significant effect on CTC or MON. Monensin dissipation half-life was found to be much shorter in the field study than in a controlled laboratory study, perhaps because of differences in microbial communities. The antimicrobials were not highly mobile. Chlortetracycline was the only antibiotic detected at 25 to 35 cm depth and only up to 2% of the initial concentration in a sandy loam soil. These antibiotics are therefore expected to degrade primarily in agricultural soils before moving to greater depths or to groundwater in significant concentrations in most agricultural systems.
Abstract-The stability of 24 chemicals, including pharmaceuticals and personal care products, and some agrochemicals on extraction media was evaluated by preloading them onto Oasis hydrophilic lipophilic balanced solid-phase extraction (SPE) cartridges and polar organic chemical integrative samplers (POCIS) followed by storage at -208C over time. After 20 months, the average loss was 11% on POCIS, with only 2,4-dichlorophenoxyacetic acid, atrazine, chlorpyrifos, and gemfibrozil showing a statistically significant decline compared with initial concentrations. Losses on SPE cartridges were below 19%, with an average loss of 9%. In addition to laboratory spiked samples, multiple POCIS deployed in wastewater-impacted surface waters and SPE extracts of these waters were stored in their original coextracted matrix for nearly two years with minimal observed losses. Errors from typical sampling, handling, and concentration estimates from POCIS sampling rates were typically AE 15 to 30% relative standard deviation, so observed storage losses are minimal for most POCIS applications. While losses during storage on SPE cartridges for 20 months were small but statistically significant for many compounds, addition of labeled internal standards prior to freezing should correct for such losses. Thus, storage of processed water samples for analysis of polar organic pollutants is viable for archival purposes or studies for which samples cannot be analyzed in the short term. Environ. Toxicol. Chem. 2013;32:337-344. # 2012 SETAC
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.