Limited research exists on rest-pause or cluster-set (CS) protocols. Acute effects of a traditional set (TS) and CS protocols of resistance exercise on serum growth hormone (GH), cortisol (C), blood lactate (BL), countermovement vertical jump (CMVJ) and standing long jump (SLJ) were compared. Eleven resistance-trained males (22.9 ± 2.6 year; 176.9 ± 10.6 cm; 78.5 ± 1.6 kg; 12.9 ± 3.1% BF) completed one repetition maximum tests for clean pull (CP), back squat (BS) and bench press (BP). Subjects were then randomly assigned to TS or CS protocols for sessions 2 and 3, and performed CP and BS lifts followed by two circuits of three sets of three exercises. GH, C, BL, CMVJ and SLJ were measured pre-exercise (Pre), mid-exercise following completion of CS or TS protocol (Mid), immediately (IP), 15 (15P) and 30 (30P) minutes post-exercise. Repeated measures ANOVAs examined differences in GH, C, BL, CMVJ and SLJ. No differences (p>0.05) existed between protocols for GH and C. GH levels 15P were elevated (p<0.05) above 30P (15.78 + 4.66 vs. 12.10 + 4.66 µg·L(-1)). C levels 30P were elevated (p<0.05) above Pre (716.85 + 102.56 vs. 524.79 + 75.79 nmol·L(-1)). Interaction (p <0.05) existed between protocol and time for BL; mid-BL was lower for CS than TS (7.69 ± 3.73 vs. 12.78 ± 1.90 mmol·L(-1)). Pooled data for CMVJ and SLJ were greater (p <0.05) across the CS protocol. The less metabolically taxing CS protocol resulted in better sustainability of jump measures.
The purpose of this investigation was to determine the influence of contraction velocity on the eccentric (ECC) and concentric (CON) torque production of the biceps brachii. After performing warm-up procedures, each male subject (n = 11) completed 3 sets of 5 maximal bilateral CON and ECC isokinetic contractions of the biceps at speeds of 90, 180, and 300 degrees x s(-1) on a Biodex System 3 dynamometer. The men received a 3-minute rest between sets and the order of exercises was randomized. Peak torque (Nm) values were obtained for CON and ECC contractions at each speed. Peak torque scores (ECC vs. CON) were compared using a t-test at each speed. A repeated measures analysis of variance was used to determine differences between speeds. ECC peak torque scores were greater than CON peak torque scores at each given speed: 90 degrees x s(-1), p = 0.0001; 180 degrees x s(-1), p = 0.0001; and 300 degrees x s(-1), p = 0.0001. No differences were found between the ECC peak torque scores (p = 0.62) at any of the speeds. Differences were found among the CON scores (p = 0.004). Post hoc analysis revealed differences between 90 degrees x s(-1) (114.61 +/- 23) and 300 degrees x s(-1) (94.17 +/- 18). These data suggest that ECC contractions of the biceps brachii were somewhat resistant to a force decrement as the result of an increase in velocity, whereas CON muscular actions of the biceps brachii were unable to maintain force as velocity increased.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.