SUMMARY Flexible endoscopy is a widely used diagnostic and therapeutic procedure. Contaminated endoscopes are the medical devices frequently associated with outbreaks of health care-associated infections. Accurate reprocessing of flexible endoscopes involves cleaning and high-level disinfection followed by rinsing and drying before storage. Most contemporary flexible endoscopes cannot be heat sterilized and are designed with multiple channels, which are difficult to clean and disinfect. The ability of bacteria to form biofilms on the inner channel surfaces can contribute to failure of the decontamination process. Implementation of microbiological surveillance of endoscope reprocessing is appropriate to detect early colonization and biofilm formation in the endoscope and to prevent contamination and infection in patients after endoscopic procedures. This review presents an overview of the infections and cross-contaminations related to flexible gastrointestinal endoscopy and bronchoscopy and illustrates the impact of biofilm on endoscope reprocessing and postendoscopic infection.
Endoscopes, including duodenoscopes, are medical devices that are frequently associated with outbreaks of nosocomial infections. We investigated an outbreak of multidrug-resistant PSEUDOMONAS AERUGINOSA sepsis affecting three patients after endoscopic retrograde cholangiopancreaticography (ERCP). Epidemiologic investigation supplemented by molecular typing revealed that one ERCP scope was the source of infection with P. AERUGINOSA. No contamination with this microorganism was found after screening of washer-disinfectors, connecting tubes, and environmental surfaces in the endoscopy center. PSEUDOMONAS isolates from blood and endoscope channels before gas sterilization with ethylene oxide (ETO) were characterized by molecular typing as "linked isolates". Though the current surveillance system did not prevent the infections in three patients, our microbiological surveillance protocol with routine culturing of endoscopes was helpful in detecting the source of contamination and probably avoided numerous cross-contaminations in other patients who underwent ERCP procedures with endoscopes.
Summary The cost effectiveness of reusable vs. single‐use flexible bronchoscopy in the peri‐operative setting has yet to be determined. We therefore aimed to determine this and hypothesised that single‐use flexible bronchoscopes are cost effective compared with reusable flexible bronchoscopes. We conducted a systematic review of the literature, seeking all reports of cross‐contamination or infection following reusable bronchoscope use in any clinical setting. We calculated the incidence of these outcomes and then determined the cost per patient of treating clinical consequences of bronchoscope‐induced infection. We also performed a micro‐costing analysis to quantify the economics of reusable flexible bronchoscopes in the peri‐operative setting from a high‐throughput tertiary centre. This produced an accurate estimate of the cost per use of reusable flexible bronchoscopes. We then performed a cost effectiveness analysis, combining the data obtained from the systematic review and micro‐costing analysis. We included 16 studies, with a reported incidence of cross‐contamination or infection of 2.8%. In the micro‐costing analysis, the total cost per use of a reusable flexible bronchoscope was calculated to be £249 sterling. The cost per use of a single‐use flexible bronchoscope was £220 sterling. The cost effectiveness analysis demonstrated that reusable flexible bronchoscopes have a cost per patient use of £511 sterling due to the costs of treatment of infection. The findings from this study suggest benefits from the use of single‐use flexible bronchoscopes in terms of cost effectiveness, cross‐contamination and resource utilisation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.