The potential for carbonate clumped isotope thermometry to independently constrain both the formation temperature of carbonate minerals and fluid oxygen isotope composition allows insight into long‐standing questions in the Earth sciences, but remaining discrepancies between calibration schemes hamper interpretation of temperature measurements. To address discrepancies between calibrations, we designed and analyzed a sample suite (41 total samples) with broad applicability across the geosciences, with an exceptionally wide range of formation temperatures, precipitation methods, and mineralogies. We see no statistically significant offset between sample types, although the comparison of calcite and dolomite remains inconclusive. When data are reduced identically, the regression defined by this study is nearly identical to that defined by four previous calibration studies that used carbonate‐based standardization; we combine these data to present a composite carbonate‐standardized regression equation. Agreement across a wide range of temperature and sample types demonstrates a unified, broadly applicable clumped isotope thermometer calibration.
The clumped isotopic composition of carbonate‐derived CO2 (denoted Δ47) is a function of carbonate formation temperature and in natural samples can act as a recorder of paleoclimate, burial, or diagenetic conditions. The absolute abundance of heavy isotopes in the universal standards VPDB and VSMOW (defined by four parameters: R13VPDB, R17VSMOW, R18VSMOW, and λ) impact calculated Δ47 values. Here, we investigate whether use of updated and more accurate values for these parameters can remove observed interlaboratory differences in the measured T‐Δ47 relationship. Using the updated parameters, we reprocess 14 published calibration data sets measured in 11 different laboratories, representing many mineralogies, bulk compositions, sample types, reaction temperatures, and sample preparation and analysis methods. Exploiting this large composite data set (n = 1,253 sample replicates), we investigate the possibility for a “universal” clumped isotope calibration. We find that applying updated parameters improves the T‐Δ47 relationship (reduces residuals) within most labs and improves overall agreement but does not eliminate all interlaboratory differences. We reaffirm earlier findings that different mineralogies do not require different calibration equations and that cleaning procedures, method of pressure baseline correction, and mass spectrometer type do not affect interlaboratory agreement. We also present new estimates of the temperature dependence of the acid digestion fractionation for Δ47 (Δ*25‐X), based on combining reprocessed data from four studies, and new theoretical equilibrium values to be used in calculation of the empirical transfer function. Overall, we have ruled out a number of possible causes of interlaboratory disagreement in the T‐Δ47 relationship, but many more remain to be investigated.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.