In this study, we report data on intraoperative complications occurring after cataract surgery in a high-volume single-center setting using a low-energy, mobile femtosecond laser. We retrospectively reviewed the medical records of patients who underwent femtosecond laser-assisted cataract surgery (FLACS) in our hospital between August 2015 and December 2019. Among the sample of 1,806 eyes of 1,131 patients (903 left and 903 right eyes), the mean age was 75.8 years (range, 21–99 years). The overall intraoperative complication rate was 0.28% (n = 5), with three cases of anterior capsule tear (0.17%) and two cases of posterior capsule tear (0.11%). No further complications occurred. This study underlines the safety of low-energy femtosecond-assisted cataract surgery in a real-world setting with a very low rate of intraoperative complications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.