Optical coherence tomography (OCT) in the spectral domain is demonstrated simultaneously at two wavelength bands centered at 800 nm and 1250 nm. A novel commercial supercontinuum laser is applied as a single low coherence broadband light source. The emission spectrum of the source is shaped by optical and spatial filtering in order to achieve an adequate double peak spectrum containing the wavelength bands 700 - 900 nm and 1100 - 1400 nm for dual-band OCT imaging and thus reducing the radiation exposure of the sample. Each wavelength band is analyzed with an individual spectrometer at an A-scan rate of about 12 kHz which enables real-time imaging for the examination of moving samples. A common path optical setup optimized for both spectral regions with a separate single fiber-based scanning unit was realized which facilitates flexible handling and easy access to the measurement area. The free-space axial resolutions were measured to be less than 4.5 microm and 7 microm at 800 nm and 1250 nm, respectively. Three-dimensional imaging ten times faster than previously reported with a signal-to-noise-ratio of above 90 dB is achieved simultaneously in both wavelength bands. Spectral domain dual-band OCT combines real-time imaging with high resolution at 800 nm and enhanced penetration depth at 1250 nm and therefore provides a well suited tool for in vivo vasodynamic measurements. Further, spatially resolved spectral features of the sample are obtained by means of comparing the backscattering properties at two different wavelength bands. The ability of dual-band OCT to enhance tissue contrast and the sensitivity of this imaging modality to wavelength-dependent sample birefringence is demonstrated.
Abstract. The optical inhomogeneity of flowing blood, which appears as a waisted double fan-shaped intensity pattern inside vessels in cross-sectional optical coherence tomography (OCT) images, was investigated for the first time. High resolution spectral domain OCT in the 1.3 μm wavelength region is used to assess this inhomogeneous intravascular backscattering of light in an in vivo mouse model and flow phantom measurements. Based on a predicted alignment of the red blood cells toward laminar shear flow, an angular modulation of the corresponding backscattering cross-section inside the vessels is assumed. In combination with the signal attenuation in depth by absorption and scattering, a simple model of the intravascular intensity modulation is derived. The suitability of the model is successfully demonstrated in the in vivo experiments and confirmed by the in vitro measurements. The observed effect appears in flowing blood only and shows a strong dependency on the shear rate. In conclusion, the shear-induced red blood cell alignment in conjunction with the vessel geometry is responsible for the observed intensity distribution. This inherent effect of blood imaging has to be considered in attenuation measurements performed with OCT. Furthermore, the analysis of the intravascular intensity pattern might be useful to evaluate flow characteristics. C 2011 Society of Photo-Optical Instrumentation Engineers (SPIE).
Stromal collagen organization has been identified as a potential prognostic indicator in a variety of cancers and other diseases accompanied by fibrosis. Changes in the connective tissue are increasingly considered for grading dysplasia and progress of oral squamous cell carcinoma, investigated mainly ex vivo by histopathology. In this study, polarization-sensitive optical coherence tomography (PS-OCT) with local phase retardation imaging is used for the first time to visualize depth-resolved (i.e., local) birefringence of healthy human oral mucosa in vivo . Depth-resolved birefringence is shown to reveal the expected local collagen organization. To demonstrate proof-of-principle, 3D image stacks were acquired at labial and lingual locations of the oral mucosa, chosen as those most commonly affected by cancerous alterations. To enable an intuitive evaluation of the birefringence images suitable for clinical application, color depth-encoded en-face projections were generated. Compared to en-face views of intensity or conventional cumulative phase retardation, we show that this novel approach offers improved visualization of the mucosal connective tissue layer in general, and reveals the collagen fiber architecture in particular. This study provides the basis for future prospective pathological and comparative in vivo studies non-invasively assessing stromal changes in conspicuous and cancerous oral lesions at different stages.
Recently, a new phase-resolved Doppler model was presented for spectral domain optical coherence tomography (SD OCT) showing that the linear relation between the axial velocity component of the obliquely moving sample and the phase difference of consecutive A-Scans does not hold true in the presence of a transverse velocity component which is neglected in the widely-used classic Doppler analysis. Besides taking note of the new non-proportional relationship of phase shift and oblique sample motion, it is essential to consider the correlation of the phase shift and its specific characteristic at certain Doppler angles for designing Doppler experiments with SD OCT. A correlation quotient is introduced to quantify the correlation of the backscattering signal in consecutive A-Scans as a function of the oblique sample motion. It was found that at certain velocities and Doppler angles no correlation of the phases of sequential A-Scans exists, even though the signal does not vanish. To indicate how the noise of the Doppler phase shift behaves for oblique movement, the standard deviation is determined as a function of the correlation quotient and the number of complex Doppler data averaged. The detailed theoretical model is validated by using a flow phantom model consisting of a 1% Intralipid flow through a 310 microm capillary. Finally, a short discussion of the presented results and the consequence for performing Doppler experiments is given.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.