Summary. A uni‐directional downflow (‘laminar’flow) ventilation system for a single‐bed patient‐room is described. It produced clean air at velocities as low as 0.12 m/sec (25 ft/min). Bacteriological studies on bed‐making done in the room showed that strains of Staphylococcus aureus carried on the nurses’external clothing were often transferred to the patients’bedclothes. This possible route of patient infection was almost eliminated when the nurses wore disposable plastic aprons over their dresses.
The aim of this study was to compare albuterol delivery in a neonatal ventilated lung model, using three delivery methods: 1) jet nebulizer; 2) chlorofluorocarbon-pressurized metered dose inhaler (CFC-MDI) actuated into an ACE(R) spacer; and 3) hydrofluoroalkane-pressurized MDI (HFA-MDI) actuated into an ACE(R) spacer. The bench model consisted of a mechanically ventilated infant test lung with ventilator settings to simulate a very low birth weight neonate with moderate lung disease. Albuterol solution (0.5%) was nebulized at the humidifier and temperature port, 125 cm and 30 cm from the Y-piece, respectively. Albuterol metered dose inhalers (MDIs) were actuated into an ACE(R) spacer that was tested in two positions: 1) inline between the endotracheal (ET) tube and the Y-piece; and 2) attached to the ET tube and administered by manual ventilation. Albuterol was collected on a filter at the distal end of the ET tube and was quantitatively analyzed by high performance liquid chromatography. Albuterol delivery by CFC-MDI (position 1, 4.8 +/- 1.0%, vs. position 2, 3.8 +/- 1.6%, P > 0.05) and HFA-MDI (position 1, 5.7 +/- 1.6%, vs. position 2, 5.5 +/- 2.4%, P > 0.05) were significantly greater than delivery by nebulization at 30 cm (0.16 +/- 0.07%) and 125 cm (0.15 +/- 0.03%) from the Y-piece (P < 0.001). A single actuation of albuterol MDI delivered the equivalent of nebulizing 2.5-3.7 mg of albuterol solution. We conclude that albuterol administered by MDI and ACE(R) spacer resulted in more efficient delivery than by nebulization in this mechanically ventilated neonatal lung model. There was no significant difference in drug delivery between CFC-MDI and HFA-MDI; nor did the placement of the spacer significantly affect drug delivery.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.