Molecular diagnosis on nasopharyngeal swabs (NPS) is the current standard for COVID-19 diagnosis, but saliva may be an alternative specimen to facilitate access to diagnosis. We compared analytic performances, feasibility and acceptability of NPS, saliva, and oral-self sampling swab for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). A prospective, multicenter study was conducted in military hospitals in France among adult outpatients attending COVID-19 diagnosis centers or hospitalized patients. For each patient, all samples were obtained and analyzed simultaneously with RT-PCR or transcription-mediated amplification method. Clinical signs, feasibility, and acceptability for each type of sample were collected. A total of 1220 patients were included, corresponding to 1205 NPS and saliva and 771 OS. Compared to NPS, the sensitivity, specificity, and kappa coefficient for tests performed on saliva were 87.8% (95% CI 83.3-92.3), 97.1% (95% CI 96.1-98.1), and 0.84 (95% CI 0.80-0.88). Analytical performances were better in symptomatic patients. Ct values were significantly lower in NPS than saliva. For OS, sensitivity was estimated to be 61.1% (95% CI 52.7-69.4) and Kappa coefficient to be 0.69 (95% CI 0.62-0.76). OS was the technique preferred by the patients (44.3%) before saliva (42.4%) and NPS (13.4%). Instructions were perceived as simple by patients (> 90%) for saliva and OS. Finally, the painful nature was estimated to be 0.9 for OS, on a scale from 0 to 10, and to be 5.3 for NPS. Performances of OS are not sufficient. Saliva is an acceptable alternative to NPS for symptomatic patient but the process required additional steps to fluidize the sample.
We report the case of a French soldier, 29-yr-old, hospitalized in intensive care unit at Begin Military Hospital for the management of a sympathomimetic syndrome associated with severe metabolic disorders. Diagnosis of voluntary caffeine overdose was made. The evolution was favorable after metabolic disorders correction, without the need for dialysis. Caffeine is a molecule free of serious adverse effects when consumed at low doses. However, when consumed at high doses, it can become toxic and lead to death. Caffeine consumption has increased in recent years and especially in French Army. This toxicity remains unknown by a large part of population. We must be vigilant because this substance misuse can lead to serious consequences.
The combined use of the Multistix 10 SG strip and of the iSTAT system appears to be an attractive solution for the biochemical investigation of CSF in medical treatment facilities with limited laboratory diagnostic capability.
Fenofibrate's interference with MDMA immunoassay was confirmed. Fenofibrate being widely prescribed, physicians had to be alerted that this treatment could lead to false-positive results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.