SUMMARY
The aim of this study was to evaluate the color stability of light-cured and dual-cured resin cements after artificial accelerated aging. Ten specimens (6-mm diameter and 2-mm thickness) for each of five resin cements were prepared: GC (dual-cured cement, GCem), Vb (light-cured cement, Variolink II only the base), Vbc (dual-cured cement, Variolink II base with catalyst), VV (light-cured cement, Variolink Veneer), and FR (flowable resin composite, light cured). The samples were polished and stored in an accelerated artificial aging machine for 308 hours (160 klx), with cycles of 120 minutes under light and 60 minutes in the dark. All aging was carried out in distilled water at 37°C and light irradiation at 765 W/m2. The samples were evaluated in a spectrophotometer before and after aging, and results were calculated according to CIEDE2000. The data were statistically analyzed (one-way analysis of variance and Tukey test, 95% confidence). The results of ΔE00 were statistically significant for the type of cement (p<0.001), with differences among tested groups. Variolink II (base only and base + catalyst) and the flowable resin were the cements with the lowest color variations after the artificial accelerated aging. Considering the values ΔE00 of acceptability and perceptibility, none of the tested cements showed acceptable values.
The aim of this study was to evaluate the failure probability of two types of abutment screws after compressive load and to analyze the stress distribution with finite element method. Sixty (60) single-tooth implant restorations were assembled on titanium implants (e-fix, A.S. Technology - Titanium Fix). The groups were divided into Conventional screw (Screw neck 1.5 ø mm) and Experimental screw (Screw neck constricted with 1.2 ø mm). Specimens were subjected to single load to failure with compressive test according ISO 14801. The fractured specimens were subjected to stereomicroscopy for measurement of remaining screws inside the implant and characterization of fracture origin. Representative specimens were analyzed by scanning electronic microscopy. For finite element method (FEM), an identical 3D model of the two in vitro test groups were used with similar conditions (30º, 100 N load). The stress in the abutment screw was analyzed by von-Mises criteria. The results of strength means were 4132.5 ± 76 MPa and 4528.2 ± 127.2 for conventional and experimental groups, respectively. During microscopy, the mean (mm) of the remaining screw piece inside the implants were 0.97 ± 0.23 and 1.32 ± 0.12 for conventional and experimental groups, respectively. In FEM, the conventional group showed stress concentered in an unfavorable region (peak of 39.23 MPa), while the experimental group showed more stress areas but less concentration than the conventional group (36.6 MPa). In using the tested experimental geometry, the abutment screw can have its strength improved, and the origin of failure can be more favorable to clinical resolution.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.