Early detection of pathogen cross-transmission events and environmental reservoirs is needed to control derived nosocomial outbreaks. Whole-genome sequencing (WGS) is considered the gold standard for outbreak confirmation, but, in most cases, it is time-consuming and has elevated costs. Consequently, the timely incorporation of WGS results to conventional epidemiology (CE) investigations for rapid outbreak detection is scarce. Fourier transform infrared spectroscopy (FTIR) is a rapid technique that establishes similarity among bacteria based on the comparison of infrared light absorption patterns of bacterial polysaccharides and has been used as a typing tool in recent studies. The aim of the present study was to evaluate the performance of the FTIR as a first-line typing tool for the identification of extended-spectrum β-lactamase-producing Klebsiella pneumoniae (ESBL-Kp) outbreaks in the hospital setting in comparison with CE investigations using WGS as the gold standard method. Sixty-three isolates of ESBL-Kp collected from 2018 to 2021 and classified according to CE were typed by both FTIR and WGS. Concordance was measured using the Adjusted Rand index (AR) and the Adjusted Wallace coefficient (AW) for both CE and FTIR clustering considering WGS as the reference method. Both AR and AW were significantly higher for FTIR clustering than CE clustering (0.475 vs. 0.134, p = 0.01, and 0.521 vs. 0.134, p = 0.009, respectively). Accordingly, FTIR inferred more true clustering relationships than CE (38/42 vs. 24/42, p = 0.001). However, a similar proportion of genomic singletons was detected by both FTIR and CE (13/21 vs. 12/21, p = 1). This study demonstrates the utility of the FTIR method as a quick, low-cost, first-line tool for the detection of ESBL-Kp outbreaks, while WGS analyses are being performed for outbreak confirmation and isolate characterization. Thus, clinical microbiology laboratories would benefit from integrating the FTIR method into CE investigations for infection control measures in the hospital setting.
Oral fluid specimens (OF) have been widely used to know the HIV prevalence in several key populations. Here, we aim to validate in OF specimens an existing HIV chemiluminiscence assay for serum specimens. Paired OF and serum specimens were collected from 83 known HIV-positives and 83 known HIV-negatives in order to validate the performance characteristics of the automated chemiluminiscence Liaison XL Murex HIV Ag/Ab assay (Diasorin Inc, Iberia) for HIV antibody detection in OF specimens. Among the previously known HIV-seropositive group, HIV antibodies were detected in 69 out of 83 OF specimens. All serum and OF specimens collected from 83 HIV seronegative individuals were negative. The sensitivity and specificity of this assay were 83.13% and 100% respectively in OF. The PPV and NPV values were 100% and 85.57% respectively. The correlation obtained between both specimens was ( K : 0.83, [95% CI : 0.748–0.915]) according to the kappa index. The ROC curve analysing the optimal cut-off of the Liaison XL Murex HIV Ag/Ab to detect positive OF specimens revealed that a cut-off of 0.497 showed sensitivity and specificity values of 98.8% and 97.59% respectively. Taking into account this cut-off, the overall sensitivity and NPV of the Liaison XL Murex HIV Ag/Ab assay could rise from 83.1 to 98.8% and from 85.5 to 97.7%, respectively. Our results suggest that the Liaison XL HIV Ag/Ab assay is suitable for the detection of HIV antibodies in OF specimens.
Macrolide and fluoroquinolone resistance (MLr/FQr) in Mycoplasma genitalium (MG) infections is concerning worldwide. Current guidelines recommend performing MLr detection in MG-positive cases to adjust antimicrobial therapy. We aimed to evaluate the usefulness of PCR followed by pyrosequencing for MLr detection in comparison with a one-step commercial assay and to assess the prevalence of MLr and FQr in Badalona, Spain. A total of 415 MG-positive samples by Allplex STI-7 (Seegene) were analyzed for MLr detection by pyrosequencing. From those, 179 samples were further analyzed for MG and MLr by ResistancePlus® MG kit (SpeeDx) and 100 of them also for fluoroquinolone resistance (FQr) by sequencing the parC gene. Regarding MG detection, Allplex and Resistance Plus® showed an overall agreement of 87%, but this value rose to 95.4% if we compare them for MLr detection. Prevalence of MLr was 23.1% in Badalona, but this rate increased to 73.7% in the HIV-positive patients cohort. FQr detection showed 3% of resistant strains. Pyrosequencing is a convenient and cheap technique for MLr detection, but one-step tools should be considered in high-throughput laboratories. Despite the fact that MLr remained moderate and FQr was low in our study, simultaneous MG and MLr detection would improve patient’s management applying resistance-guided treatment strategies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.