It is difficult to describe the taste of Processed Aconite Root (PAR) because it contains toxic compounds, and tasting poses some risk to the examiner. Therefore, there is no description of the taste of PAR in the latest Japanese Pharmacopoeia, although the taste of crude drugs has been regulated as a criterion for judgment. In this study, we revealed the objective taste of PAR by using a taste-sensing system. The PAR samples examined were classified into four types by how the samples were processed: PAR1 processed by autoclaving; PAR2-a processed by autoclaving after rinsing in salt (sodium chloride) solution; PAR2-h processed by heating after rinsing in calcium chloride solution; PAR3 processed by treating with hydrated lime after rinsing in salt solution. The most characteristic taste factor of PAR is an aftertaste of cationic bitterness, which was detected in all PAR sample solutions, even at the concentration of 0.1 mg/ml. In addition, anionic bitterness and saltiness were detected in all sample solutions at 1 mg/ml. Furthermore, umami was detected in the PAR1, PAR2-a, and PAR3 sample solutions at 1 mg/ml. Detailing the analyses of the four taste factors on the four sample types, we found each type has its own characteristic taste pattern. On the basis of these results, we proposed a method for discriminating one PAR type from another by using the system.
Quantitative NMR (qNMR) is applied to determine the absolute quantitative value of analytical standards for HPLC-based quantification. We have previously reported the optimal and reproducible sample preparation method for qNMR of hygroscopic reagents, such as saikosaponin a, which is used as an analytical standard in the assay of crude drug section of Japanese Pharmacopoeia (JP). In this study, we examined the absolute purity determination of a hygroscopic substance, indocyanine green (ICG), listed in the Japanese Pharmaceutical Codex 2002, using qNMR for standardization by focusing on the adaptation of ICG to JP. The purity of ICG, as an official non-Pharmacopoeial reference standard (non-PRS), had high variation (86.12 ± 2.70%) when preparing qNMR samples under non-controlled humidity (a conventional method). Additionally, residual ethanol (0.26 ± 0.11%) was observed in the non-PRS ICG. Next, the purity of non-PRS ICG was determined via qNMR when preparing samples under controlled humidity using a saturated sodium bromide solution. The purity was 84.19 ± 0.47% with a lower variation than that under non-controlled humidity. Moreover, ethanol signal almost disappeared. We estimated that residual ethanol in non-PRS ICG was replaced with water under controlled humidity. Subsequently, qNMR analysis was performed when preparing samples under controlled humidity in a constant temperature and humidity box. It showed excellent results with the lowest variation (82.26 ± 0.19%). As the use of a constant temperature and humidity box resulted in the lowest variability, it is recommended to use the control box if the reference ICG standard is needed for JP assays.
The side effects of kwao keur dietary supplements (obtained from the tuberous root of Pueraria mirifica) have recently been reported by the Ministry of Health, Labour and Welfare, Japan. To control the quality of kwao keur products, its ingredients need to be maintained by characteristic marker compounds, such as miroestrol, deoxymiroestrol, and kwakhurin (KWA). In this study, we described the facile synthesis of KWA, a marker compound of P. mirifica. Our revised synthetic method produced KWA with shorter steps and higher yield than the reported method. Furthermore, the absolute purity of KWA was determined by quantitative NMR analysis for standardization as a reagent, and its purity was 92.62 0.12%.
Quantitative NMR (qNMR) has been developed as an absolute quantitation method to determine the purity or content of organic compounds including marker compounds in crude drugs. The``qNMR test'' has been introduced into the crude-drug section of the Japanese Pharmacopoeia (JP) for determining the purity of reagents used for the assay in the JP. In Supplement II to the JP 17th edition published in June 2019,ˆfteen compounds adopted qNMR test were listed as the reagents for the assay. To establish the``qNMR test'' in the crude drug section of the JP, there were several problems to be solved. Previously, we reported that the handling impurity signals from reference substances and targeted marker compounds, chemical shifts of reference substances, and peak unity of signals of targeted marker compounds are important factors to conduct qNMR measurements with intended accuracy. In this study, we investigated that the hygroscopicity of reagents could cause the changes in the compounds' purity depending on increasing their water content. Twenty-one standard products used for the crude-drug test in JP were examined by water sorption-desorption analysis, and ginsenosides and saikosaponins were found to be hygroscopic. To prepare a sample solution of saikosaponin b 2 for qNMR analysis, samples need to be maintained for 18 h at 25°C and 76% relative humidity; further, samples need to be weighed at the same humidity for the qNMR analysis.
Quantitative 1 H-NMR ( 1 H-qNMR) is useful for determining the absolute purity of organic molecules; however, it is sometimes difficult to identify the target signal(s) for quantitation because of their overlap and complexity. Therefore, we focused on the 31 P nucleus because of the simplicity of its signals and previously reported 31 P-qNMR in D2O. Here we report 31 P-qNMR of an organophosphorus compound, sofosbuvir (SOF), which is soluble in organic solvents. Phosphonoacetic acid (PAA) and 1,4-BTMSB-d4 were used as reference standards for 31 P-qNMR and 1 H-qNMR, respectively, in methanol-d4. The purity of SOF determined by 31 P-qNMR was 100.63 ± 0.95%, whereas that determined by 1 H-qNMR was 99.07 ± 0.50%. The average half bandwidths of the 31 P signal of PAA and SOF were 3.38 ± 2.39 Hz and 2.22 ± 0.19 Hz, respectively, suggesting that the T2 relaxation time of the PAA signal was shorter than that of SOF and varied among test laboratories. This difference most likely arose from the instability in the chemical shift due to the deuterium exchange of the acidic protons of PAA, which decreased the integrated intensity of the PAA signal. Next, an aprotic solvent, DMSO-d6, was used as the dissolving solvent with PAA and DSS-d6 as reference standards for 31 P-qNMR and 1 H-qNMR, respectively. SOF purities determined by 31 P-qNMR and 1 H-qNMR were 99.10 ± 0.30% and 99.44 ± 0.29%, respectively. SOF purities determined by 31 P-qNMR agreed with the established 1 H-qNMR values, suggesting that an aprotic solvent is preferable for 31 P-qNMR because it is unnecessary to consider the effect of deuterium exchange.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.