We compared respiratory parameters during anaesthesia with sevoflurane and isoflurane through a laryngeal mask airway (LMA). Children were anaesthetized with O2 and air with 2.3% (1MAC) sevoflurane (n = 20) or 1.5% (1MAC) isoflurane (n = 20). After insertion of LMA, patients were allowed to breathe spontaneously and respiratory rate (RR) and PECO2 were measured (presurgery state). After the measurement, anaesthetic concentration was increased to 1.3 MAC (3.0% sevoflurane or 2.0% isoflurane) and surgical stimulation was added. Fifteen min after incision, the measurements were again performed (during surgery). In the sevoflurane group, mean RR and PECO2 were 32 breaths.min-1, and 6.0 kPa (45 mmHg) respectively, before surgery, and 35 breaths.min-1 and 7.0 kPa (52 mmHg) during surgery. In the isoflurane group, mean RR and PECO2 were 32 breaths.min-1 and 6.1 kPa (46 mmHg) respectively, before surgery, and 37 breaths.min-1 and 6.7 kPa (52 mmHg) during surgery. There were no statistical differences between the two anaesthetic groups. Clinical respiratory and cardiovascular parameters during spontaneous breathing with LMA in children are similar during sevoflurane and isoflurane anaesthesia.
Patients with epilepsy on long term antiepileptic drug (AED) therapy deserve special consideration not only concerning seizure control but also the effect on anaesthetic metabolism and hepatorenal functions. In the present study, we examined the effects of sevoflurane anaesthesia on plasma inorganic fluoride (F-) level and hepatorenal function in patients with and without AED therapy. Twenty-two patients (12 with AEDs = AED group, and ten without AEDs = control group = C group), ASA I, who were free of hepatorenal disease, received approximately 2-3 h sevoflurane anaesthesia. Plasma F- analysis was performed at the stages of: 1) induction of anaesthesia, 2) conclusion of anaesthesia, 3) 15 h after the conclusion of anaesthesia, using an ion-selective electrode calibrated with a standard solution of sodium fluoride. Pre- and postoperative hepatic (aspartate aminotransferase, alanine aminotransferase, alkaline phosphatase, total bilirubin) and renal (blood urea nitrogen, creatinine) function was tested. There were no significant differences between the two groups in the average age (AED group = 9.4 and control group = 10.1 y.o.), body weight, duration of anesthesia, and MAC hours (2.6 and 2.4). The mean peak F- levels were 15.5 and 13.6 microM, in AED and C groups (not significant), respectively. No patient exhibited F- values greater than 50 microM, the hypothetical nephrotoxic threshold. The patients showed no abnormal values either in hepatic or renal function tests postoperatively. These results suggest approximately 2-3 h sevoflurane anaesthesia to be safe in patients taking AEDs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.