The cytotoxicity test using MTT on HeLa cells (HeLa-MTT) was evaluated as an alternative method to the Draize eye irritation test (Draize test) by six to eight laboratories. The 50% inhibition concentration (EC(50)) for MTT reduction was calculated. A total of thirty-nine test chemicals were examined. The average interlaboratory coefficient of variation (CV) of the present assay was 25%. Comparison of the in vitro test results with those of the Draize test revealed a correlation coefficient of -0.799 between the log(EC(50)) value and the maximum average total score (MAS) for a 10% solution or suspension. The following characteristics of HeLa-MTT have become apparent through this validation: (1) HeLa-MTT could be applied to all substances including water-insoluble substances, esters, a colour additive, and a substance which is known to directly reduce MTT; (2) there is good interlaboratory reproducibility and strong correlation between HeLa-MTT and Draize MAS; (3) results for strong acids, alkanolamines and alcohols (lower mono-ol) clearly deviate from other samples with respect to the correlation between HeLa-MTT and Draize MAS. These results suggest that HeLa-MTT may be useful for predicting the Draize MAS if definite criteria can be established for applicable compounds.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.