Purpose:To evaluate the diagnostic performance of magnetic resonance (MR) imaging-estimated proton density fat fraction (PDFF) for assessing hepatic steatosis in nonalcoholic fatty liver disease (NAFLD) by using centrally scored histopathologic validation as the reference standard. Materials and Methods:This prospectively designed, cross-sectional, internal review board-approved, HIPAA-compliant study was conducted in 77 patients who had NAFLD and liver biopsy. MR imaging-PDFF was estimated from magnitude-based low flip angle multiecho gradient-recalled echo images after T2* correction and multifrequency fat modeling. Histopathologic scoring was obtained by consensus of the Nonalcoholic Steatohepatitis (NASH) Clinical Research Network Pathology Committee. Spearman correlation, additivity and variance stabilization for regression for exploring the effect of a number of potential confounders, and receiver operating characteristic analyses were performed. Results:Liver MR imaging-PDFF was systematically higher, with higher histologic steatosis grade (P , .001), and was significantly correlated with histologic steatosis grade (r = 0.69, P , .001). The correlation was not confounded by age, sex, lobular inflammation, hepatocellular ballooning, NASH diagnosis, fibrosis, or magnetic field strength (P = .65). Area under the receiver operating characteristic curves was 0.989 (95% confidence interval: 0.968, 1.000) for distinguishing patients with steatosis grade 0 (n = 5) from those with grade 1 or higher (n = 72), 0.825 (95% confidence interval: 0.734, 0.915) to distinguish those with grade 1 or lower (n = 31) from those with grade 2 or higher (n = 46), and 0.893 (95% confidence interval: 0.809, 0.977) to distinguish those with grade 2 or lower (n = 58) from those with grade 3 (n = 19). Conclusion:MR imaging-PDFF showed promise for assessment of hepatic steatosis grade in patients with NAFLD. For validation, further studies with larger sample sizes are needed.q RSNA, 2013
A novel microfluidic device for high-throughput particle separation using a viscoelastic fluid, which enables the rapid detection of extremely rare malaria parasites by using PCR analysis, is proposed. Our device consists of two segments: the 1st stage for sheathless pre-alignment and the 2nd stage for separation based on size-dependent viscoelasticity-induced lateral migration. The use of a high-aspect ratio channel and a viscoelastic polymer solution with low viscosity enables high-throughput processing. The device performance was first optimized using synthetic particles. A mixture of 2 and 10 μm particles was focused at the center plane in the 1st stage. The smaller particles, serving as surrogates for malaria parasites, were subsequently separated in the 2nd stage with a recovery rate of ∼96% at 400 μl min(-1). Finally, separation of the malaria parasites from the white blood cells was performed. At 400 μl min(-1), almost all white blood cells were removed and the malaria parasites were separated with a ∼94% recovery rate and ∼99% purity. Although the initial concentration of the malaria parasites was too low to be detected by PCR analysis, WBC depletion and buffer removal increased the parasite concentration sufficiently such that PCR detection was possible.
A novel microfluidic device which consists of two stages for particle focusing and separation using a viscoelastic fluid has been developed. A circular capillary tube was used for three-dimensional particle pre-alignment before the separation process, which was inserted in a polydimethylsiloxane microchannel. Particles with diameters of 5 and 10 μm were focused at the centerline in the capillary tube, and the location of particles was initialized at the first bifurcation. Then, 5 and 10 μm particles were successfully separated in the expansion region based on size-dependent lateral migration, with ∼99% separation efficiency. The proposed device was further applied to separation of MCF-7 cells from leukocytes. Based on the cell size distribution, an approximate size cutoff for separation was determined to be 16 μm. At 200 μl/min, 94% of MCF-7 cells were separated with the purity of ∼97%. According to the trypan blue exclusion assay, high viability (∼90%) could be achieved for the separated MCF-7 cells. The use of a commercially available capillary tube enables the device to be highly versatile in dealing with particles in a wide size range by using capillary tubes with different inner diameters.
A low-cost portable device was developed with a coin vibration motor for quantification of red blood cell aggregation.
The identification of each cell type is essential for understanding multicellular communities. Antibodies set as biomarkers have been the main toolbox for cell-type recognition, and chemical probes are emerging surrogates. Herein we report the first small-molecule probe, CDgB, to discriminate B lymphocytes from T lymphocytes, which was previously impossible without the help of antibodies. Through the study of the origin of cell specificity, we discovered an unexpected novel mechanism of membraneoriented live-cell distinction. B cells maintain higher flexibility in their cell membrane than T cells and accumulate the lipid-like probe CDgB more preferably. Because B and T cells share common ancestors, we tracked the cell membrane changes of the progenitor cells and disclosed the dynamic reorganization of the membrane properties over the lymphocyte differentiation progress. This study casts an orthogonal strategy for the small-molecule cell identifier and enriches the toolbox for live-cell distinction from complex cell communities.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.